NORTHBOROUGH, MA —
OSHA Inspection: APR CONSTRUCTION INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of APR CONSTRUCTION INC in LOT 5 LINCOLN ST, NORTHBOROUGH, MA 01532 (NAICS 238130). OSHA activity number 344147285.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- APR CONSTRUCTION INC
- Site address
- LOT 5 LINCOLN ST
- City
- NORTHBOROUGH
- State
- MA
- ZIP
- 01532
- Mailing
- 34 HAWTHORNE ST APT 2, CHELSEA, MA 02150
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 9
- Ownership type
- A
Citations
8 citations on file for this inspection.
1903.19 C01
- Issued
- Dec 12, 2019
- Abate by
- Jan 16, 2020
- Penalty
- Initial $319 · Current $319
General-duty citation text
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: As of December 3, 2019, the employer had not certified to OSHA within 10 calendar days that abatement was completed for the violation Citation1 Item1, Citation 1 Item 2, Citation 1 Item 3a, Citation 1 Item 3b, Citation 1 Item 4 and Citation 1 Item 5, from Inspection number 1414728 issued on September 11, 2019 with a final order date of October 23, 2019. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29CFR1903.19(d)(1).
Recent events (1)
- — Z (O) $319
1903.19 D01
- Issued
- Dec 12, 2019
- Abate by
- Jan 16, 2020
- Penalty
- Initial $319 · Current $319
General-duty citation text
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required. As of December 3, 2019 , the employer had not submitted to the Agency documents that abatement had been completed for serious violation indicated by the Agency included Citation1 Item 1 and Citation 1 Item 5, from inspection number 1414728, issued September 11, 2019 with a final order date of October 5, 2019. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29CFR1903.19(d)(1).
Recent events (1)
- — Z (O) $319
1926.501 B13
- Issued
- Sep 11, 2019
- Abate by
- Oct 7, 2019
- Penalty
- Initial $3,978 · Current $3,978
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system: Lot 5 Lincoln St., Northborough, MA: On or about July 10, 2019, an employee was observed working at a height of 12 feet 4 inches above a lower level on the rear roof of this residence without any form of fall protection in place. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29CFR1903.19(d)(1).
Recent events (1)
- — Z (S) $3978
1926.501 B14
- Issued
- Sep 11, 2019
- Abate by
- Oct 7, 2019
- Penalty
- Initial $2,842 · Current $2,842
General-duty citation text
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached) where the outside bottom edge of the wall opening is 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 m) above the walking/working surface, was not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system: Lot 5 Lincoln St., Northborough, MA: On or about July 10, 2019, employees were observed walking by and working in front of window openings on the second story which was 12 feet 4 inches above a lower level of this residence and these openings were not protected in any way to prevent the employees from falls through these openings.
Recent events (1)
- — Z (S) $2842
1926.503 A01
- Issued
- Sep 11, 2019
- Abate by
- Oct 7, 2019
- Penalty
- Initial $2,842 · Current $2,842
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards: Lot 5 Lincoln St., Northborough, MA: On or about July 10, 2019, employees were exposed to fall hazards while working at heights greater than 6 feet above lower levels and the employer had not provided employees with a training program to minimize fall hazards.
Recent events (1)
- — Z (S) $2842
1926.503 B01
- Issued
- Sep 11, 2019
- Abate by
- Oct 7, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section (fall protection training) by preparing a written certification record which contained the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer: (a) Lot 5 Lincoln St., Northborough, MA: On or about July 10, 2019, The employer did not prepare a written certification verifying that employees had been trained in hazards related to falls from elevation.
Recent events (1)
- — Z (S) $0
1926.1052 C01
- Issued
- Sep 11, 2019
- Abate by
- Sep 17, 2019
- Penalty
- Initial $2,273 · Current $2,273
General-duty citation text
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: Lot 5 Lincoln St., Northborough, MA: On or about July 10, 2019, employees were observed using a staircase which had no handrails to access the second floor work area
Recent events (1)
- — Z (S) $2273
1926.1053 B01
- Issued
- Sep 11, 2019
- Abate by
- Oct 15, 2019
- Penalty
- Initial $3,978 · Current $3,978
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access: Lot 5 Lincoln St., Northborough, MA: On or about July 10, 2019, employees were observed using a ladder that did not extend 3 feet past the upper landing surface to access their roof top work location. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29CFR1903.19(d)(1).
Recent events (1)
- — Z (S) $3978
More inspections at APR Construction INC
View APR Construction INC's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344147285.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.