RIVERVIEW, FL —
OSHA Inspection: DYNASTY BUILDING SOLUTIONS LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DYNASTY BUILDING SOLUTIONS LLC in 12306 DAWN VISTA DRIVE, RIVERVIEW, FL 33578 (NAICS 238160). OSHA activity number 344152293.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DYNASTY BUILDING SOLUTIONS LLC
- Site address
- 12306 DAWN VISTA DRIVE
- City
- RIVERVIEW
- State
- FL
- ZIP
- 33578
- Mailing
- 3914 N HWY 301 #200, TAMPA, FL 33619
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.102 A01
- Issued
- Jan 14, 2020
- Abate by
- Jan 27, 2020
- Penalty
- Initial $7,956 · Current $3,978 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury: a) On or about July 15, 2019, employees were exposed to eye injuries while using Metabo HPT Pneumatic Nail Guns while installing shingles in that they were not wearing safety glasses meeting the ANSI/ISEA Z87.1-2010, Occupational and Educational Personal Eye and Face Protection Devices. b) On or about July 15, 2019, employees were exposed to eye injuries while using Metabo HPT Pneumatic Nail Guns while installing shingles in that they were using sun glasses not meeting the ANSI/ISEA Z87.1-2010, Occupational and Educational Personal Eye and Face Protection Devices.
Recent events (2)
- — I (S) $3978
- — Z (S) $7956
1926.501 B13
- Issued
- Jan 14, 2020
- Abate by
- Jan 27, 2020
- Penalty
- Initial $5,304 · Current $2,652 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On or about July 15, 2019, employees without fall protection were exposed to falls while conducting re-roofing activities approximately 7 feet 10 inches from the ground.
Recent events (2)
- — I (S) $2652
- — Z (S) $5304
1926.1053 B01
- Issued
- Jan 14, 2020
- Abate by
- Jan 27, 2020
- Penalty
- Initial $3,978 · Current $1,989 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about July 15, 2019, employees performing re-roofing job tasks on a single story residential building were exposed to a 7 foot fall hazard, in that, a Gorilla Ladders 18 foot Reach Multi-Position Ladder MPX-17 extended 11 feet was not extended 3 feet above the landing surface of the roof.
Recent events (2)
- — I (S) $1989
- — Z (S) $3978
1926.1053 B05 I
- Issued
- Jan 14, 2020
- Abate by
- Jan 27, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder: a) On or about July 15, 2019, employees conducting re-roofing activities using a Gorilla 18 foot Reach Multi -Position Ladder was not used at an adequate angle in that it was extended eleven feet and the distance between the foot of the ladder and the wall was four feet, seven and 5/8 inches.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.503 A01
- Issued
- Jan 14, 2020
- Abate by
- Feb 18, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) On or about July 15, 2019, employees engaged in re-roofing activities of a residential single story 5:12 pitch roof were not able to recognize the procedures to minimize fall hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.1060 A01 III
- Issued
- Jan 14, 2020
- Abate by
- Jan 27, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1060(a)(1)(iii): The employer did not ensure that each employee using ladders and/or stairways had been trained by a competent person in the proper construction, use, placement, and care in handling the ladders and/or stairways: (a) On or about July 15, 2019, employees engaged in re-roofing activities who were using a 18 foot Gorilla Ladders Reach Multi-Position Ladder for access and egress to a single story residential roof.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Dynasty Building Solutions LLC
View Dynasty Building Solutions LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344152293.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.