Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RIVER DRIVE SERVICE CENTER INC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of RIVER DRIVE SERVICE CENTER INC in 4613 NORTH FRONT STREET, HARRISBURG, PA 17110 (NAICS 811111). OSHA activity number 344153994.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch River Drive Service Center INC — free Get an email when a new federal OSHA severe-injury report for River Drive Service Center INC is published. One employer, no account, unsubscribe in one click.
Site address
4613 NORTH FRONT STREET
City
HARRISBURG
State
PA
ZIP
17110
Mailing
4613 NORTH FRONT STREET, HARRISBURG, PA 17110
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
25
Ownership type
A

4 citations on file for this inspection.

1910.147 C01

Other-than-serious 1 instance 1 exposed
Issued
Jan 10, 2020
Abate by
Jul 6, 2020
Penalty
Initial $13,260 · Current $13,260
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.    a) River Drive Service Center Inc - The employer did not implement a sufficient energy control program for the repair and maintenance of commercial vehicles. On or about July 13, 2019, the employer did not address hazards specific to removal, repair and maintenance of truck body components. The tailgate was not adequately blocked to prevent unexpected shift or movement of the tailgate during torch cutting operations.        Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (O) $13260
  • — Z (S) $13260

1910.147 C04 I

Other-than-serious 1 instance 1 exposed
Issued
Jan 10, 2020
Abate by
Jul 6, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:     a) River Drive Service Center Inc - The employer did not ensure that sufficient lockout tagout procedures were developed, and documented and did not ensure that employees de-energized, isolated, blocked and secured all sources of energy before servicing equipment such as the Heil trash body, which resulted in a fatal struck-by injury, on or about July 13, 2019.    Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.178 A04

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jan 10, 2020
Abate by
Feb 28, 2020
Penalty
Initial $5,304 · Current $0 Reduced
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval:  River Driver Service Center, Inc: On or about July 13, 2019 the employer utilized "free rigging" with alloy chains off the tines of the Windham W-15 STD forklift for a below-the-tine lift to support the tailgate section of Heil trash truck body during removal. The forklift manufacturer's or a professional registered engineer's written approval was not sought for this modification prior to this lift activity.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5304

1910.178 L03 II I

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Jan 10, 2020
Abate by
Jan 30, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(3)(ii)(I): Powered industrial truck operators did not receive initial training in other unique or potentially hazardous conditions of the workplace that could affect safe operation:  River Driver Service Center, Inc: On or about July 13, 2019 the employer did not train designated employee(s) on the use of the Windham W-15 STD forklift for a below-the-tine support, hoist and transfer of large parts from commercial trucks.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View River Drive Service Center INC's full OSHA safety record →