Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RPM-CO.COM ENTERPRISES LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of RPM-CO.COM ENTERPRISES LLC in 27888 S.E. US HWY 19, OLD TOWN, FL 32680 (NAICS 336212). OSHA activity number 344160213.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rpm-Co.Com Enterprises LLC — free Get an email when a new federal OSHA severe-injury report for Rpm-Co.Com Enterprises LLC is published. One employer, no account, unsubscribe in one click.
Site address
27888 S.E. US HWY 19
City
OLD TOWN
State
FL
ZIP
32680
Mailing
27888 S.E. US HWY 19, OLD TOWN, FL 32680
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336212
Employees
3
Ownership type
A

11 citations on file for this inspection.

1910.252 A01 I

Other-than-serious 1 instance 3 exposed
Issued
Nov 18, 2019
Abate by
Jan 7, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.252(a)(1)(i): When the object to be welded or cut could not be readily moved, all movable fire hazards in the vicinity were not taken to a safe place:  a. On or about July 17, 2019, in the fabrication shop, the employer failed to ensure that combustible and flammable  materials, such as cardboard and category 2 flammable liquids, were removed from adjacent areas where welding activities were conducted, exposing the employees to fire hazards.    OR IN THE ALTERNATIVE: 29 CFR 1910.252(a)(2)(xv): Cutting or welding was permitted in areas that were not made fire safe by removing combustibles or protecting combustibles from ignition sources:
Recent events (1)
  • — Z (O) $0

1910.252 A02 II

Other-than-serious 1 instance 3 exposed
Issued
Nov 18, 2019
Abate by
Jan 7, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.252(a)(2)(ii): Suitable extinguishing equipment was not maintained in a state of readiness for instant use:  a. On or about July 17, 2019, in the fabrication shop, the employer failed to ensure that a suitable fire extinguisher was available for employee self rescue where welding activities were conducted, exposing the employees to fire hazards.
Recent events (1)
  • — Z (O) $0

1910.253 B04 I

Other-than-serious 2 instances 3 exposed
Issued
Nov 18, 2019
Abate by
Jan 7, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire;  a. On or about July 17, 2019, in the fabrication shop, the employer failed to ensure that oxygen cylinders were not stored near highly combustible materials, oil or grease, such as diesel fuel stored inside a container marked as "ArmorTrac Economy Tractor Hydraulic Fluid", exposing the employees to fire hazards.  b. On or about July 17, 2019, in the fabrication shop, the employer failed to ensure that oxygen cylinders were not stored near acetylene cylinders, exposing the employees to fire hazards.
Recent events (1)
  • — Z (O) $0

1910.252 B02 III

Other-than-serious 1 instance 3 exposed
Issued
Nov 18, 2019
Abate by
Jan 7, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:  a. On or about July 17, 2019, in the fabrication shop, the employer failed to ensure that employees working near welding activities were protected from exposure to UV radiation by suitable noncombustible or flame-proof screens or shield.
Recent events (1)
  • — Z (O) $0

1910.304 G05

Other-than-serious 1 instance 3 exposed
Issued
Nov 18, 2019
Abate by
Jan 7, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  a. On or about July 17, 2019, in the fabrication shop, the employer failed to ensure that the path to ground from a multiple adapter providing power to a  "One-29 BlueDri Air Mover" and an electric fan was effective and continuous.
Recent events (1)
  • — Z (O) $0

1910.334 A02 II

Other-than-serious 1 instance 3 exposed
Issued
Nov 18, 2019
Abate by
Jan 7, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service:  a. On or about July 17, 2019, in the fabrication shop, the employer failed to remove from service an electrical extension cord with damaged protective sheet.
Recent events (1)
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 3 exposed
Issued
Nov 18, 2019
Abate by
Jan 7, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  a) On or about July 17, 2019, in the general fabrication area, the employer failed to develop, implement and maintain a written Hazard Communication Program for the protection of the employees using hazardous chemicals, including but not limited to diesel fuel, welding and cutting gases such as Oxygen, Acetylene and Weld-Mix shielding gas, paints such as "Pro-Tech Acrystar Modified Alkid Enamel", lubricants such as "Blaster PB Penetrating Catalyst" and "Viking ER70S-6 MIG" welding wire.
Recent events (1)
  • — Z (O) $0

1910.1200 E01 I

Other-than-serious 1 instance 3 exposed
Issued
Nov 18, 2019
Abate by
Jan 7, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet.  a) On or about July 17, 2019, in the general fabrication area, the employer failed to create a list of all hazardous chemicals used and stored in the workplace, including but not limited to diesel fuel, welding and cutting gases such as Oxygen, Acetylene and Weld-Mix shielding gas, paints such as "Pro-Tech Acrystar Modified Alkid Enamel", lubricants such as "Blaster PB Penetrating Catalyst" and "Viking ER70S-6 MIG" welding wire.
Recent events (1)
  • — Z (O) $0

1910.1200 F06 I

Other-than-serious 1 instance 3 exposed
Issued
Nov 18, 2019
Abate by
Jan 7, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6)(i): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v)  a) On or about July 17, 2019, in the general fabrication area next to the north entrance, two 5 USGAL buckets of marked as "ArmorTrac Economy Tractor Hydraulic Fluid" were used to contained and store diesel fuel, were not properly marked and identified.
Recent events (1)
  • — Z (O) $0

1910.1200 G01

Other-than-serious 1 instance 3 exposed
Issued
Nov 18, 2019
Abate by
Jan 7, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use:  a) On or about July 17, 2019, in the general fabrication area, the employer failed to keep a copy of the Safety Data Sheets of the chemicals used and stores in the workplace available to employees using hazardous chemicals, including but not limited to diesel fuel, welding and cutting gases such as Oxygen, Acetylene and Weld-Mix shielding gas, paints such as "Pro-Tech Acrystar Modified Alkid Enamel", lubricants such as "Blaster PB Penetrating Catalyst" and "Viking ER70S-6 MIG" welding wire.
Recent events (1)
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 3 exposed
Issued
Nov 18, 2019
Abate by
Jan 7, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) On or about July 17, 2019, in the general fabrication area, the employer failed to provide Hazard Communication training to employees using hazardous chemicals, including but not limited to diesel fuel, welding and cutting gases such as Oxygen, Acetylene and Weld-Mix shielding gas, paints such as "Pro-Tech Acrystar Modified Alkid Enamel", lubricants such as "Blaster PB Penetrating Catalyst" and "Viking ER70S-6 MIG" welding wire.