WASHINGTON, DC —
OSHA Inspection: CV ROOFING LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CV ROOFING LLC in 3433 SUMMIT CRT NE, WASHINGTON, DC 20009 (NAICS 238160). OSHA activity number 344161609.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CV ROOFING LLC
- Site address
- 3433 SUMMIT CRT NE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20009
- Mailing
- 6889 TIFTON CRT, MANASSAS, VA 20108
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- Jan 9, 2020
- Abate by
- Jan 17, 2020
- Penalty
- Initial $2,898 · Current $1,700 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about July 10, 2019; second floor; employees working on ground level were not wearing head protection while picking up debris from the overhead roofing work. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $1700
- — Z (S) $2898
1926.501 B13
- Issued
- Jan 9, 2020
- Penalty
- Initial $3,978 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about July 10, 2019, roof area; employees were observed conducting roofing work on a residential home without fall protection in place to protect them falling approximately 22-feet to ground level. No abatement certification or documentation required for this item
Recent events (2)
- — I (S) $2500
- — Z (S) $3978
1926.1053 B01
- Issued
- Jan 9, 2020
- Penalty
- Initial $3,978 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed a) On or about July 10, 2019, second-floor area; the side rail on the extension ladder used during the roofing process was approximately 10-inches above the roof surface exposing the employees to a fall of approximately 22-feet to ground level. No abatement certification or documentation required for this item
Recent events (2)
- — I (S) $2500
- — Z (S) $3978
1926.1053 B08
- Issued
- Jan 9, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder. a) On or about July 10, 2019, front area; the extension ladder used to access the roof area was not secured to prevent it from displacement exposing the employees to a fall of approximately 22-feet to ground level. No abatement certification or documentation required for this item
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.503 B01
- Issued
- Jan 9, 2020
- Abate by
- Jan 17, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) On or about July 10, 2019; throughout the site; the employer had not certified the fall protection training to employees that may be exposed to fall hazards 6-feet or greater as well as methods to protect themselves while conducting their assigned duties. In accordance with 29 CFR 1903.19(d), abatement ce1tification is required for this violation (using the Certification of Corrective Action Worksheet.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238160)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344161609.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.