WASHINGTON, DC —
OSHA Inspection: JCI CONSTRUCTION LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JCI CONSTRUCTION LLC in 3010 UNIVERSITY TERR, WASHINGTON, DC 20016 (NAICS 238130). OSHA activity number 344161682.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JCI CONSTRUCTION LLC
- Site address
- 3010 UNIVERSITY TERR
- City
- WASHINGTON
- State
- DC
- ZIP
- 20016
- Mailing
- 9611 GLEN VIEW DR, CLINTON, MD 20735
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.102 A01
- Issued
- Jan 16, 2020
- Penalty
- Initial $2,949 · Current $2,949
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a) On or about July 17, 2019; second floor; employees were not wearing the provided eye protection while operating portable tools such as but not limited to nail guns. No abatement certification or documentation required for this item.
Recent events (1)
- — Z (S) $2949
1926.501 B13
- Issued
- Jan 16, 2020
- Penalty
- Initial $4,048 · Current $4,048
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about July 17, 2019, second-floor area; employees were observed walking the top-plate while framing the new residential home without fall protection in place to protect them falling approximately 10-feet to the wooden floor or 23-feet to ground level. No abatement certification or documentation required for this item.
Recent events (1)
- — Z (S) $4048
1926.1053 B01
- Issued
- Jan 16, 2020
- Abate by
- Jan 24, 2020
- Penalty
- Initial $4,048 · Current $4,048
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) On or about July 17, 2019, second-floor area; the side rail on the step-ladder used during the framing process was 2-feet below the surface exposing the employees to a fall of approximately 10-feet to the wooden deck. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $4048
1926.1053 B13
- Issued
- Jan 16, 2020
- Abate by
- Jan 27, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) On or about July 17, 2019; second floor; employees were using step-ladders to access the top-plate area that was too short for the application causing the employees to use the top step of the ladder exposing them to a potential fall hazard. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $0
1926.503 B01
- Issued
- Jan 16, 2020
- Abate by
- Jan 27, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer: a) On or about July 17, 2019; the employer had not certified the fall protection training to employees who were exposed to fall hazards up to approximately 23-feet while conducting framing work. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (O) $0
More inspections at JCI Construction LLC
View JCI Construction LLC's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344161682.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.