Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JCI CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JCI CONSTRUCTION LLC in 3010 UNIVERSITY TERR, WASHINGTON, DC 20016 (NAICS 238130). OSHA activity number 344161682.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JCI Construction LLC — free Get an email when a new federal OSHA severe-injury report for JCI Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
3010 UNIVERSITY TERR
City
WASHINGTON
State
DC
ZIP
20016
Mailing
9611 GLEN VIEW DR, CLINTON, MD 20735
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 16, 2020
Penalty
Initial $2,949 · Current $2,949
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.  a) On or about July 17, 2019; second floor; employees were not wearing the provided eye protection while operating portable tools such as but not limited to nail guns.     No abatement certification or documentation required for this item.
Recent events (1)
  • — Z (S) $2949

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 16, 2020
Penalty
Initial $4,048 · Current $4,048
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) On or about July 17, 2019, second-floor area; employees were observed walking the top-plate while framing the new residential home without fall protection in place to protect them falling approximately 10-feet to the wooden floor or 23-feet to ground level.   No abatement certification or documentation required for this item.
Recent events (1)
  • — Z (S) $4048

1926.1053 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 16, 2020
Abate by
Jan 24, 2020
Penalty
Initial $4,048 · Current $4,048
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  a) On or about July 17, 2019, second-floor area; the side rail on the step-ladder used during the framing process was 2-feet below the surface exposing the employees to a fall of approximately 10-feet to the wooden deck.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $4048

1926.1053 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 16, 2020
Abate by
Jan 27, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:   a) On or about July 17, 2019; second floor; employees were using step-ladders to access the top-plate area that was too short for the application causing the employees to use the top step of the ladder exposing them to a potential fall hazard.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

1926.503 B01

Other-than-serious 1 instance 2 exposed
Issued
Jan 16, 2020
Abate by
Jan 27, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer:  a) On or about July 17, 2019; the employer had not certified the fall protection training to employees who were exposed to fall hazards up to approximately 23-feet while conducting framing work.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (O) $0

View JCI Construction LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344161682.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.