Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FLORIDA FOLIAGE LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FLORIDA FOLIAGE LLC in 2312 CLARK STREET UNIT 11-12, APOPKA, FL 32703 (NAICS 424930). OSHA activity number 344163548.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Florida Foliage LLC — free Get an email when a new federal OSHA severe-injury report for Florida Foliage LLC is published. One employer, no account, unsubscribe in one click.
Establishment
FLORIDA FOLIAGE LLC
Site address
2312 CLARK STREET UNIT 11-12
City
APOPKA
State
FL
ZIP
32703
Mailing
2312 CLARK STREET UNIT 11-12, APOPKA, FL 32703
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424930
Employees
3
Ownership type
A

3 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 12, 2019
Penalty
Initial $1,705 · Current $1,023 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery or equipment were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  a. On or about 07/01/2019, at the job site - the guillotine blade guard was removed from the hand operated paper cutter exposing employees to amputation hazards at the point of operation.
Recent events (2)
  • — I (S) $1023
  • — Z (S) $1705

1910.157 C01

Other-than-serious 1 instance 1 exposed
Issued
Dec 12, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a. On or about 07/18/2019, at the job site - a fire extinguisher was not readily identified.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B02

Other-than-serious 1 instance 5 exposed
Issued
Dec 12, 2019
Abate by
Dec 24, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a. On or about 07/18/2019, at the job site - a conduit opening on the side of an electrical panel was not closed with a cover, therefore, exposing employees to an electrical contact hazard to more than 50 volts.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344163548.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.