MARBLE FALLS, TX —
OSHA Inspection: GIBRALTAR US, INC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of GIBRALTAR US, INC in 4303 INNOVATION LOOP, MARBLE FALLS, TX 78654 (NAICS 332999). OSHA activity number 344163688.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GIBRALTAR US, INC
- Site address
- 4303 INNOVATION LOOP
- City
- MARBLE FALLS
- State
- TX
- ZIP
- 78654
- Mailing
- 4303 INNOVATION LOOP, MARBLE FALLS, TX 78654
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 70
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.132 D02
- Issued
- Oct 15, 2019
- Abate by
- Dec 3, 2019
- Penalty
- Initial $5,115 · Current $3,069 Reduced
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment: On or about July 17, 2019 and times prior thereto, the employer had not verified through a written certification which meets the requirements of the standard, that workplace hazard assessments for personal protective equipment (PPE) had been conducted, exposing employees to the hazards of being struck by materials.
Recent events (2)
- — I (S) $3069
- — Z (S) $5115
1910.134 C01
- Issued
- Oct 15, 2019
- Abate by
- Dec 3, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:(a) On or about July 17, 2019 and times prior thereto, the employer had not developed or implemented a written respiratory program for employees required to wear respirators while painting and priming products, exposing employees to chemical inhalation hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.136 A
- Issued
- Oct 15, 2019
- Abate by
- Dec 3, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.136(a): The employer did not ensure that each affected employee used protective footwear when working in areas where there was a danger of foot injuries due to falling or rolling objects, or objects piercing the sole, and where such employee's feet were exposed to electrical hazards: On or about July 17, 2019 and times prior thereto, the employer did not require the use of foot protection for employees working the shop area, exposing employees to the hazard of their toes or feet being crushed by metal objects.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C04 I
- Issued
- Oct 15, 2019
- Abate by
- Dec 3, 2019
- Penalty
- Initial $5,115 · Current $3,069 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about July 17, 2019 and times prior thereto, the employer had not developed machine specific procedures for the control of hazardous energy for employees required to do maintenance on equipment including, but not limited to, the bandsaw, exposing employees to the hazards of electric shock and being struck by moving parts.
Recent events (2)
- — I (S) $3069
- — Z (S) $5115
1910.253 B02 II
- Issued
- Oct 15, 2019
- Abate by
- Nov 8, 2019
- Penalty
- Initial $5,115 · Current $3,069 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: On or about July 17, 2019 and times prior thereto, an acetylene cylinder located outside near the generator was not stored in a secure manner to prevent tipping over, exposing employees to the hazards of explosions and fire.
Recent events (2)
- — I (S) $3069
- — Z (S) $5115
1910.253 B02 IV
- Issued
- Oct 15, 2019
- Abate by
- Nov 8, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: On or about July 17, 2019 and times prior thereto, an acetylene cylinder stored outside near the generator did not have it's valve cap on, exposing employees to the hazards of explosions and fire.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 B04 III
- Issued
- Oct 15, 2019
- Abate by
- Nov 8, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least: On or about July 17, 2019 and times prior thereto, oxygen cylinders were stored less than 20 feet from acetylene cylinders, exposing employees to the hazard of fire.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Oct 15, 2019
- Abate by
- Nov 8, 2019
- Penalty
- Initial $5,115 · Current $3,069 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about July 17, 2019 and times prior thereto, a four plex knock-out type receptacle, designed for mounting, located in the paint area, was used as a portable power supply to a drill used as a paint mixer, exposing employees to the hazard of electrical shock.
Recent events (2)
- — I (S) $3069
- — Z (S) $5115
1910.334 A02 II
- Issued
- Oct 15, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: On or about July 17, 2019 and at times prior thereto, the cord powering the paint mixer located in the outside painting area was damaged, exposing employees to the hazard of electrical shock.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 F01
- Issued
- Oct 15, 2019
- Abate by
- Nov 8, 2019
- Penalty
- Initial $5,115 · Current $3,069 Reduced
General-duty citation text
29 CFR 1910.303(f)(1): Each disconnecting means required by Subpart S of Part 1910 for motors and appliances was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: On or about July 17, 2019 and times prior thereto, the circuit breakers controlling welding machines in the panel box labeled 'A', located on the left side of the facility, were not legibly marked to show their purpose, exposing employees to electrical hazards.
Recent events (2)
- — I (S) $3069
- — Z (S) $5115
1910.1200 E01
- Issued
- Oct 15, 2019
- Abate by
- Dec 3, 2019
- Penalty
- Initial $5,115 · Current $3,069 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): On or about July 17, 2019 and at times prior thereto, the employer did not have a complete written hazard communication program implemented for employees using paint, primer, mild steel, and welding gases, exposing employees to inhalation, absorption, and/or ingestion hazards of chemicals.
Recent events (2)
- — I (S) $3069
- — Z (S) $5115
1904.29 B01
- Issued
- Oct 15, 2019
- Abate by
- Nov 8, 2019
- Penalty
- Initial $1,706 · Current $1,024 Reduced
General-duty citation text
29 CFR 1904.29(b)(1): A log of all recordable work-related injuries and illness (OSHA Form 300 or equivalent) was not completed in the detail required by the regulation. On or about July 17, 2019 and times prior thereto, the OSHA 300 Form for the calendar year 2019 had deficiencies that materially impaired the understandability of the records in that the objects and/or actions that caused the injuries were not noted in the log entries. Abatement Note: Previous years' logs had the same deficiencies.
Recent events (2)
- — I (O) $1023.6
- — Z (O) $1706
More inspections at Gibraltar US, INC
View Gibraltar US, INC's full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344163688.