Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GATEWAY WAREHOUSE OF GEORGIA, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GATEWAY WAREHOUSE OF GEORGIA, INC. in 50 KENT DRIVE, CARTERSVILLE, GA 30121 (NAICS 493110). OSHA activity number 344164090.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gateway Warehouse of Georgia, INC. — free Get an email when a new federal OSHA severe-injury report for Gateway Warehouse of Georgia, INC. is published. One employer, no account, unsubscribe in one click.
Site address
50 KENT DRIVE
City
CARTERSVILLE
State
GA
ZIP
30121
Mailing
50 KENT DRIVE, CARTERSVILLE, GA 30121
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
30
Ownership type
A

3 citations on file for this inspection.

1910.151 C

Other-than-serious 1 instance 1 exposed
Issued
Dec 31, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.  a) Warehouse, Battery Charging Station: On or about July 18, 2019, and at times prior, the employer exposed employees to eye injuries, in that frequent inspections of a Self-Contained Eyewash Station (Honeywell Porta Stream II) were not performed to ensure it was in a suitable condition for immediate use.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.304 B04 II B

Other-than-serious 1 instance 15 exposed
Issued
Dec 31, 2019
Penalty
Initial $904 · Current $542 Reduced
29 CFR 1910.304(b)(4)(ii)(B): Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle may not supply a total cord- and plug-connected load in excess of the maximum specified in Table S-4.  a) Repack Area: On or about July 18, 2019, and at times prior, the employer allowed employees to work in close proximity to overloaded electrical outlets thus exposing them to fire hazards while utilizing electrical fans (Power Plus Drum Fans). The fans overloaded the 120 Volt - 15 Amp electrical branch.
Recent events (2)
  • — I (O) $542.4
  • — Z (O) $904

1910.305 G01 IV A

Other-than-serious 1 instance 15 exposed
Issued
Dec 31, 2019
Penalty
Initial $904 · Current $542 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables may not be used as a substitute for the fixed wiring of a structure.  a) Repack Area: On or about July 18, 2019, and at times prior, the employer allowed employees to be exposed to electrical shock and fire hazards while utilizing electrical fans (Power Plus Drum Fans) that were connected to an extension cord and tied to the building structure.
Recent events (2)
  • — I (O) $542.4
  • — Z (O) $904

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344164090.