CARTERSVILLE, GA —
OSHA Inspection: GATEWAY WAREHOUSE OF GEORGIA, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GATEWAY WAREHOUSE OF GEORGIA, INC. in 50 KENT DRIVE, CARTERSVILLE, GA 30121 (NAICS 493110). OSHA activity number 344164090.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GATEWAY WAREHOUSE OF GEORGIA, INC.
- Site address
- 50 KENT DRIVE
- City
- CARTERSVILLE
- State
- GA
- ZIP
- 30121
- Mailing
- 50 KENT DRIVE, CARTERSVILLE, GA 30121
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 30
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.151 C
- Issued
- Dec 31, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use. a) Warehouse, Battery Charging Station: On or about July 18, 2019, and at times prior, the employer exposed employees to eye injuries, in that frequent inspections of a Self-Contained Eyewash Station (Honeywell Porta Stream II) were not performed to ensure it was in a suitable condition for immediate use.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.304 B04 II B
- Issued
- Dec 31, 2019
- Penalty
- Initial $904 · Current $542 Reduced
General-duty citation text
29 CFR 1910.304(b)(4)(ii)(B): Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle may not supply a total cord- and plug-connected load in excess of the maximum specified in Table S-4. a) Repack Area: On or about July 18, 2019, and at times prior, the employer allowed employees to work in close proximity to overloaded electrical outlets thus exposing them to fire hazards while utilizing electrical fans (Power Plus Drum Fans). The fans overloaded the 120 Volt - 15 Amp electrical branch.
Recent events (2)
- — I (O) $542.4
- — Z (O) $904
1910.305 G01 IV A
- Issued
- Dec 31, 2019
- Penalty
- Initial $904 · Current $542 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables may not be used as a substitute for the fixed wiring of a structure. a) Repack Area: On or about July 18, 2019, and at times prior, the employer allowed employees to be exposed to electrical shock and fire hazards while utilizing electrical fans (Power Plus Drum Fans) that were connected to an extension cord and tied to the building structure.
Recent events (2)
- — I (O) $542.4
- — Z (O) $904
More inspections in this industry (NAICS 493110)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344164090.