BROOKLYN, NY —
OSHA Inspection: TESTA ELECTRIC CO. INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TESTA ELECTRIC CO. INC. in 7620 15TH AVENUE, BROOKLYN, NY 11228 (NAICS 238210). OSHA activity number 344165717.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TESTA ELECTRIC CO. INC.
- Site address
- 7620 15TH AVENUE
- City
- BROOKLYN
- State
- NY
- ZIP
- 11228
- Mailing
- 1435 65TH STREET, BROOKLYN, NY 11219
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 2
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.95 A
- Issued
- Oct 25, 2019
- Penalty
- Initial $3,789 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact. Site: 7620 15th Avenue, Brooklyn, NY 11228 Location: a) Towards the South-East, 15th Avenue, entrance on the roof of the 1st floor a) On or about 07/16/2019, an employee was tapping into the main power line service drop, with an orange extension cord ,without the use of proper Personal Protective Equipment such as, but not limited to, electrically rated glasses and face shield for Arc Flash.
Recent events (3)
- — F (S) $1500
- — C (S) $3789
- — Z (S) $3789
1926.97 C02 VIII
- Issued
- Oct 25, 2019
- Abate by
- Nov 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.97(c)(2)(viii): Electrical protective equipment was not subjected to periodic electrical tests. Test voltages and the maximum intervals between tests were not in accordance with Table E-4 and Table E-5. In the alternative, 29 CFR 1926.97(c)(2)(xii): The employer did not certify that the equipment has been tested in accordance with the requirements of paragraphs (c)(2)(viii) of this section. The certification shall identify the equipment that passed the test and the date it was tested and shall be made available upon request. Site: 7620 15th Avenue, Brooklyn, NY 11228 Location: a) On the South-East roof of the 1st floor. a) The employer provided employees with a pair of Marigold Industrial insulating rubber gloves that were not tested, and labeled, within the past 12 months prior to first service issue date. The condition was noted at or about 07/16/2019.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.403 B02
- Issued
- Oct 25, 2019
- Penalty
- Initial $3,031 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification. Site: 7620 15th Avenue, Brooklyn, NY 11228 Location: a) Towards the South-East, 15th Avenue, entrance on the roof of the 1st floor to the Driveway floor On or about 07/16/2019, a power strip was used outdoors for a purpose that it was not intended for in construction. Employees energized the power strip by using an orange electrical cord which was tapped into the main line service drop. This power strip was used to energize a hand-held power drive pipe-threading machine and battery charger packs.
Recent events (3)
- — F (S) $1500
- — C (S) $3031
- — Z (S) $3031
1926.404 B01 II
- Issued
- Oct 25, 2019
- Abate by
- Nov 4, 2019
- Penalty
- Initial $3,789 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection. Site: 7620 15th Avenue, Brooklyn, NY 11228 Location: a) Towards the South-East, 15th Avenue, entrance on the roof of the 1st floor and driveway On or about 07/16/2019, an employee used an extension cord to energize a power drive pipe-threading machine and battery charger packs without the use of a ground fault circuit interrupter.
Recent events (3)
- — F (S) $0
- — C (S) $3789
- — Z (S) $3789
1926.405 G02 III
- Issued
- Oct 25, 2019
- Penalty
- Initial $3,031 · Current $0 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap. Site: 7620 15th Avenue, Brooklyn, NY 11228 Location: Towards the South-East, 15th Avenue, entrance on the roof of the 1st floor to the Driveway floor a) The flexible cord was not used in continuous length without a splice or tap. An employee was using a spliced flexible extension cord to energize the power strip by tapping into the main power line service drop.
Recent events (3)
- — F (S) $0
- — C (S) $3031
- — Z (S) $3031
1926.416 A01
- Issued
- Oct 25, 2019
- Penalty
- Initial $5,304 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means. Site: 7620 15th Avenue, Brooklyn, NY 11228 Location: a) Towards the South-East, 15th Avenue, entrance on the roof of the 1st floor On or about 07/16/2019, An employee was working without de-energizing the live circuit and without the required personal protective equipment. Employees were on the roof and tapping into the main power line service drop to energize the power strip.
Recent events (3)
- — F (S) $2500
- — C (S) $5304
- — Z (S) $5304
1926.501 B01
- Issued
- Oct 25, 2019
- Penalty
- Initial $5,304 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Site: 7620 15th Avenue, Brooklyn, NY 11228 Location: a) Towards the South-East, 15th Avenue, entrance on the roof of the 1st floor of the driveway On or about 07/16/2019, an employee was working on the roof of the 1st floor and exposed to falling approximately 12 feet to the lower level. Employees were on the roof and working on the connection between the main power line service drop and the power strip, without the use of guardrails, safety nets, or personal fall arrest systems.
Recent events (3)
- — F (S) $2500
- — C (S) $5304
- — Z (S) $5304
1926.1053 B01
- Issued
- Oct 25, 2019
- Penalty
- Initial $3,789 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. Site: 7620 15th Avenue, Brooklyn, NY 11228 Location: a) Towards the South-East, 15th Avenue, entrance on the roof of the 1st floor and concrete driveway. On or about 07/16/2019, an employee was working on the roof of the 1st floor and exposed to falling approximately 12 feet to the next lower level while using an extension ladder for access to and from the roof. The ladder was placed on the driveway exterior wall of the house, which was not the landing level that employees accessed.
Recent events (3)
- — F (S) $0
- — C (S) $3789
- — Z (S) $3789
More inspections at Testa Electric CO. INC.
View Testa Electric CO. INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238210)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344165717.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.