OSHA Inspection: PS FURNITURE, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PS FURNITURE, INC. in 801 HIGH STREET, CONNEAUTVILLE, PA 16406 (NAICS 337127). OSHA activity number 344170253.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch PS Furniture, INC. — free Get an email when a new federal OSHA severe-injury report for PS Furniture, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
PS FURNITURE, INC.
Site address
801 HIGH STREET
City
CONNEAUTVILLE
State
PA
ZIP
16406
Mailing
801 HIGH STREET, CONNEAUTVILLE, PA 16406
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337127
Employees
49
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 29, 2019
Abate by
Sep 6, 2019
Penalty
Initial $4,508 · Current $2,500 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):      A.)  PS Furniture, Inc. - On or about 7/22/19, and at times prior thereto, employees were performing servicing and maintenance on equipment/machinery that included, but was not limited to, the thermoform machine, the robot, and the tubing bender.  The lockout/tagout procedures did not list the magnitudes of energy, specific procedure steps for shutting down the equipment, or how to test the equipment to verify proper de-energization.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4508

1910.147 C06 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 29, 2019
Abate by
Sep 6, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:      A.)  PS Furniture, Inc. - On or about 7/22/19, and at times prior thereto, employees were performing servicing and maintenance on equipment/machinery that included, but was not limited to, the thermoform machine, the robot, and the tubing bender.  The company had not performed a periodic inspection of the procedures since December 2017.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.254 B04 IV

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 29, 2019
Penalty
Initial $4,508 · Current $2,500 Reduced
29 CFR 1910.254(b)(4)(iv): Terminals for welding leads were not protected from accidental contact by personnel or metal objects:      A.)  PS Furniture, Inc. Max Edge Buildling - On or about 7/22/19, and at times prior thereto, the welding terminals on the Idealarc Lincoln arc welder (R3S-#25/ M110) were not covered to prevent accidental contact with the terminals.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4508

1910.303 G01 II

Other-than-serious 1 instance 2 exposed
Issued
Jul 29, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  A.)  PS Furniture, Inc.; Max Edge Building - On or about 7/22/19, and at times prior thereto, the area in front of a 240 volt panel box was used for storage.  Items stored in the area, included, but were not limited to, cardboard boxes and Styrofoam.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View PS Furniture, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344170253.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.