DORAVILLE, GA ·
OSHA Inspection: ARGOS USA LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ARGOS USA LLC in 2395 WEAVER WAY, DORAVILLE, GA 30340 (NAICS 327320). OSHA activity number 344175070.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARGOS USA LLC
- Site address
- 2395 WEAVER WAY
- City
- DORAVILLE
- State
- GA
- ZIP
- 30340
- Mailing
- 3015 WINWARD PLAZA SUITE 300, ALPHARETTA, GA 30005
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327320
- Employees
- 30
- Ownership type
- Private (A)
Citations
9 citations on file for this inspection.
1910.28 B11 II
- Issued
- Oct 2, 2019
- Abate by
- Oct 15, 2019
- Penalty
- Initial $5,683 · Current $4,433 Reduced
General-duty citation text
29 CFR 1910.28(b)(11)(ii): The employer did not ensure that each flight of stairs having at least 3 treads and at least 4 risers is equipped with stair rail systems and handrails as follows: Guardrail systems: Argos USA LLC, Doraville, GA - At the top parking lot steps, employees were exposed to a fall hazard while using stairs having 2 open sides, width less than 44 inches with 4 treads and 5 risers that did not have a mid-rail as part of the stair rail system, on or about April 10, 2019. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $4432.74
- · Z (S) $5683
1910.35
- Issued
- Oct 2, 2019
- Abate by
- Oct 29, 2019
- Penalty
- Initial $9,472 · Current $7,388 Reduced
General-duty citation text
29 CFR 1910.35: The employer did not demonstrate compliance with the exit route provisions of NFPA 101-2009, Section 7.1.10.1, as adopted by OSHA reference standard 1910.6 in that: "means of egress was not continuously maintained free of all obstructions or impediments to full instant use in the case of fir or other emergency: Argos USA LLC, Doraville, GA - On the elevated walkway (catwalk) leading to the main office, employees were exposed to a trip/fall hazard from 2 to 4 inch edge elevation and pathway depression in an exit route that could cause a tripping hazard during an emergency escape from the elevated work area, on or about April 10, 2019. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $7388.16
- · Z (S) $9472
1910.147 C04 I
- Issued
- Oct 2, 2019
- Abate by
- Nov 20, 2019
- Penalty
- Initial $13,260 · Current $10,343 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Argos USA LLC, Doraville, GA - Employees were exposed to caught-by hazards while lubricating or repairing mechanical power transmission equipment, and the employer had not developed specific lockout/tagout procedure to prevent unexpected startup of the equipment, on or about April 10, 2019. Equipment includes, but is not limited to the top of silos and mixer. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $10342.8
- · Z (S) $13260
1910.147 C07 I A
- Issued
- Oct 2, 2019
- Abate by
- Nov 20, 2019
- Penalty
- Initial $13,260 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): The employer did not ensure that each authorized employee(s) receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: Argos USA LLC, Doraville, GA - In the production area, authorized employees were exposed caught-by hazards while lubricating mechanical power transmission equipment without receiving training on utilizing a specific lockout / tagout procedure to prevent unexpected startup of the equipment, on or about April 10, 2019. Equipment includes, but is not limited to the top of silos and mixer. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $0
- · Z (S) $13260
1910.212 A01
- Issued
- Oct 2, 2019
- Abate by
- Nov 20, 2019
- Penalty
- Initial $7,577 · Current $5,910 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Argos USA LLC, Doraville, GA Employees were exposed to caught-by or struck-by hazards associated with unguarded belt rollers operating in the tunnel, on or about April 10, 2019. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $5910.06
- · Z (S) $7577
1910.303 B07
- Issued
- Oct 2, 2019
- Abate by
- Oct 8, 2019
- Penalty
- Initial $7,577 · Current $5,910 Reduced
General-duty citation text
29 CFR 1910.303(b)(7): Electric equipment was not installed in a neat and workman like manner: Argos USA LLC, Doraville, GA - Diesel storage area - Electrical circuit wiring was not installed or connected to a terminal in a manner that was neat and professional, on or about April 10, 2019. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $5910.06
- · Z (S) $7577
1910.303 G02 I
- Issued
- Oct 2, 2019
- Abate by
- Oct 29, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any other approved means: Argos USA LLC, Doraville, GA - In the tunnel area, the solenoid panel with 120 terminals did not have cover doors or doors were left open exposing employees to electrocution hazards, on or about April 10, 2019. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 A02 X
- Issued
- Oct 2, 2019
- Abate by
- Oct 29, 2019
- Penalty
- Initial $7,577 · Current $6,016 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords were not protected from accidental damage, as might be caused for example, by sharp corners, projections, and doorways or other pinch points: Argos USA LLC, Doraville, GA - Throughout the facility flexible extension cords were used for equipment power application in areas where they could be damaged by moving vehicle or equipment, exposing employees electrical shock hazards, on or about April 10, 2019. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $6016.18
- · Z (S) $7577
1910.305 G02 III
- Issued
- Oct 2, 2019
- Abate by
- Oct 15, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: Argos USA LLC, Doraville, GA - In the tunnel area at the solenoid panel, a flexible cord was connected to a terminal in a manner that did not prevent pull from being directly on the connection point for the cord, exposing employees to a potential electric shock hazard, on or about April 10, 2019. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Argos USA LLC
View Argos USA LLC's full OSHA safety record →
More inspections in this industry (NAICS 327320)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344175070.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.