PENNSAUKEN, NJ —
OSHA Inspection: CPK TECHNOLOGIES INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CPK TECHNOLOGIES INC. in 7145 COLONIAL LANE, PENNSAUKEN, NJ 08109 (NAICS 339112). OSHA activity number 344179171.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CPK TECHNOLOGIES INC.
- Site address
- 7145 COLONIAL LANE
- City
- PENNSAUKEN
- State
- NJ
- ZIP
- 08109
- Mailing
- 7145 COLONIAL LANE, PENNSAUKEN, NJ 08109
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339112
- Employees
- 56
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.133 A01
- Issued
- Nov 22, 2019
- Abate by
- Jan 30, 2020
- Penalty
- Initial $6,630 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) CPK Technologies Inc. DBA Tecomet - Finishing Department area: The employer did not ensure that employees using, mixing and diluting caustic chemicals including but not limited to: Nitric Acid, Citric Acid, etc., were using safety googles to protect them against splash hazards, on or about 07/22/2019.
Recent events (2)
- — I (S) $3500
- — Z (S) $6630
1910.133 A02
- Issued
- Nov 22, 2019
- Abate by
- Jan 30, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.133(a)(2): The employer shall ensure that each affected employee uses eye protection that provides side protection when there is a hazard from flying objects. Detachable side protectors meeting the pertinent requirements of this section are acceptable. a) CPK Technologies Inc. DBA Tecomet - Finishing Department area: The employer did not ensure that employees using, mixing and diluting caustic chemicals including but not limited to: Nitric Acid, Citric Acid, etc., were using side shields while wearing prescription glasses, observed on or about 07/22/2019.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C02 II
- Issued
- Nov 22, 2019
- Abate by
- Jan 30, 2020
- Penalty
- Initial $3,978 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: a) CPK Technologies Inc. DBA Tecomet - Finishing Department: Company employees from the Finishing Department use the half mask negative pressure respirators equipped with Honeywell cartridges for organic vapors part # N75001L, NBR 13696 on a voluntary basis for parts washing and cleaning operations. At the time of the inspection the company did not implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator. Condition noted on or about 07/22/2019.
Recent events (2)
- — I (S) $1500
- — Z (S) $3978
1910.134 E01
- Issued
- Nov 22, 2019
- Abate by
- Jan 30, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) CPK Technologies Inc. DBA Tecomet - Finishing Department: Company employees from the Finishing Department use the half mask negative pressure respirators equipped with Honeywell cartridges for organic vapors part # N75001L, NBR 13696 on a voluntary basis. At the time of the inspection the company did not provide a medical evaluation to employees to determine their ability to use a respirator. Condition noted on or about 07/22/2019.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.151 C
- Issued
- Nov 22, 2019
- Penalty
- Initial $6,630 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) CPK Technologies Inc. DBA Tecomet - Finishing Department: The employer did not provide an eye wash station within the work area that provides 15 minutes of continue flow for flushing of the eyes when employees can come in contact with corrosive chemicals including but not limited to: Nitric Acid or Citric Acid. Occurred on or about 07/22/2019.
Recent events (2)
- — I (S) $3500
- — Z (S) $6630
1910.1200 H01
- Issued
- Nov 22, 2019
- Abate by
- Jan 30, 2020
- Penalty
- Initial $6,630 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) CPK Technologies Inc. DBA Tecomet - Finishing Department: The employer had not provided information and training to employees on chemicals they used in the workplace such as but not limited to: Nitric Acid, Citric Acid, etc., occurred on or about 07/22/2019.
Recent events (2)
- — I (S) $3500
- — Z (S) $6630
1910.134 C02 I
- Issued
- Nov 22, 2019
- Abate by
- Jan 30, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a) CPK Technologies Inc. DBA Tecomet - Finishing Department: The employer did not provide a copy of appendix D to employees using filtering face piece dust masks., on or about 07/22/2019.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 339112)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344179171.