Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: PANTALIONE CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PANTALIONE CONSTRUCTION LLC in 4445/57 CENTRAL AVE, OCEAN CITY, NJ 08226 (NAICS 238110). OSHA activity number 344180344.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pantalione Construction LLC for free Get an email when a new federal OSHA severe-injury report for Pantalione Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
4445/57 CENTRAL AVE
City
OCEAN CITY
State
NJ
ZIP
08226
Mailing
1047 HARDING HIGHWAY, BUENA, NJ 08310
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Last modified
Data loaded
NAICS code
238110
Employees
10
Ownership type
Private (A)

3 citations on file for this inspection.

1926.451 E01

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 14, 2020
Abate by
Mar 5, 2020
Penalty
Initial $3,978 · Current $2,400 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces shall not be used as a means of access:    a)  Northeast corner of Central & 45th, Ocean City, South side of house:  Employees climbed down the cross braces and end frames, from the approximate 33-35 foot level of the six frame high by approximately 16 foot long by approximately 5 foot wide fabricated frame scaffold, on or about 07/25/2019.    NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • · I (S) $2400
  • · Z (S) $3978

1926.451 G01

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 14, 2020
Abate by
Mar 5, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:    a)    Northeast corner of Central & 45th, Ocean City, South side of house:  Employees without proper fall protection were working approximately 33-35 feet above ground level from a fabricated frame scaffold, 6 frames high by approximately 16 feet long by approximately 5 feet wide for the platform between the uprights and from the side bracket platform on the side of the scaffold facing the chimney approximately 16 feet long by 1 1/2 -2 feet wide, on or about 07/25/2019.     NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 14, 2020
Abate by
Mar 5, 2020
Penalty
Initial $3,978 · Current $2,400 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     a)    Northeast corner of Central & 45th, Ocean City, South side of house:  Employee without any fall protection worked from the 4.25:12 pitch roof, approximately 33-35 feet above ground level while installing the brick façade for the exterior surface of the chimney, on or about 07/25/2019.    NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.