BARNESVILLE, PA —
OSHA Inspection: JCA ROOFING & REMODELING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JCA ROOFING & REMODELING in 580 PINE CREEK DR., BARNESVILLE, PA 18214 (NAICS 238160). OSHA activity number 344181755.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JCA ROOFING & REMODELING
- Site address
- 580 PINE CREEK DR.
- City
- BARNESVILLE
- State
- PA
- ZIP
- 18214
- Mailing
- 150 W. 47TH ST., READING, PA 19606
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Aug 6, 2019
- Abate by
- Aug 16, 2019
- Penalty
- Initial $3,978 · Current $3,978
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 580 Pine Creek Dr., Barnesville, PA: Each employee engaged in residential roofing activities at heights of 7 to 15 feet above the ground level were not protected from falling, as observed on or about July 23, 2019. Abatement Certification and Documentation Required.
Recent events (1)
- — Z (S) $3978
1926.404 B01 I
- Issued
- Aug 6, 2019
- Abate by
- Aug 16, 2019
- Penalty
- Initial $1,705 · Current $1,705
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. a) 580 Pine Creek Dr., Barnesville, PA: Employees using flexible cords to power equipment on the site were not protected by the use of ground fault circuit interrupters (GFCI) or an assured equipment grounding conductor program (AEGCP), as observed on or about July 23, 2019. Abatement Certification Required.
Recent events (1)
- — Z (S) $1705
1926.1053 B01
- Issued
- Aug 6, 2019
- Abate by
- Aug 16, 2019
- Penalty
- Initial $1,705 · Current $1,705
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) 580 Pine Creek Dr., Barnesville, PA: Extension ladders used to gain access to both the upper roof and lower porch roof of the residence did not extend at least 3 feet above the upper landing surfaces, as observed on or about July 23, 2019. Abatement Certification Required.
Recent events (1)
- — Z (S) $1705
More inspections at JCA Roofing & Remodeling
View JCA Roofing & Remodeling's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344181755.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.