Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: USMAIL ELECTRIC, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of USMAIL ELECTRIC, INC. in TACO BELL, 136 NORTH GENESEE STREET, UTICA, NY 13502 (NAICS 238210). OSHA activity number 344181961.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Usmail Electric, INC. — free Get an email when a new federal OSHA severe-injury report for Usmail Electric, INC. is published. One employer, no account, unsubscribe in one click.
Site address
TACO BELL, 136 NORTH GENESEE STREET
City
UTICA
State
NY
ZIP
13502
Mailing
800 CALDER AVENUE, YORKVILLE, NY 13495
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
30
Ownership type
A

2 citations on file for this inspection.

1926.1053 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 19, 2019
Penalty
Initial $5,304 · Current $3,978 Reduced
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:    a) South side of building, on or about 7-25-19:  One employee was working while standing on the top step and top platform of a step ladder, exposing the employee to a fall hazard of 5 feet.
Recent events (2)
  • — I (S) $3978
  • — Z (S) $5304

1926.1053 B14

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(14): Crossbracing on the rear section of stepladders, not designed and provided with steps for climbing on both front and rear sections, was used for climbing:    a) South side of building, on or about 7-25-19:  One employee was working while straddling the top of a step ladder and standing on the rear bracing member, exposing the employee to a fall hazard of 5 feet.