Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: QUALSERV SOLUTIONS, LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of QUALSERV SOLUTIONS, LLC in 7400 SOUTH 28TH STREET, FORT SMITH, AR 72908 (NAICS 337127). OSHA activity number 344182381.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Qualserv Solutions, LLC — free Get an email when a new federal OSHA severe-injury report for Qualserv Solutions, LLC is published. One employer, no account, unsubscribe in one click.
Site address
7400 SOUTH 28TH STREET
City
FORT SMITH
State
AR
ZIP
72908
Mailing
7400 SOUTH 28TH STREET, FORT SMITH, AR 72908
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337127
Employees
300
Ownership type
A

2 citations on file for this inspection.

1910.1026 D02 I

Serious Gravity 1 1 instance 8 exposed
Issued
Oct 28, 2019
Penalty
Initial $5,683 · Current $2,273 Reduced
29 CFR 1910.1026(d)(2)(i): The employer using the scheduled monitoring option did not perform initial monitoring to determine the 8-hour time-weighted average exposure to chromium (VI) for each employee on the basis of a sufficient number of personal breathing zone air samples to accurately characterize full shift exposure on each shift, for each job classification, in each work area:  (a) For the employees welding stainless steel in the welding department on or about August 7, 2019 and times prior thereto,  the employer did not conduct initial monitoring to determine employee exposure to Chromium VI for employee welding in steel containing chemicals such as, but not limited to, 308 Stainless Steel welding rod containing 19.5-22% Chromium and 301 Stainless Steel sheet metal containing 17.577% Chromium.
Recent events (2)
  • — I (S) $2273.2
  • — Z (S) $5683

1910.303 B02

Other-than-serious 1 instance 4 exposed
Issued
Oct 28, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a) For the employees working in the metal fabrication area on or about July 25, 2019 and times prior thereto,  the employer was using a power strip with a UL rating for residential use that was plugged into an extension cord that was plugged into the power cord of a shop fan to power the fan.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344182381.