SUNRISE, FL —
OSHA Inspection: RITEWAY SYSTEMS, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of RITEWAY SYSTEMS, INC. in 3003 N UNIVERSITY DRIVE, SUNRISE, FL 33322 (NAICS 238910). OSHA activity number 344184130.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RITEWAY SYSTEMS, INC.
- Site address
- 3003 N UNIVERSITY DRIVE
- City
- SUNRISE
- State
- FL
- ZIP
- 33322
- Mailing
- 3071 NW 64TH AVE, SUNRISE, FL 33313
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 25
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.21 B02
- Issued
- Jan 24, 2020
- Abate by
- Feb 20, 2020
- Penalty
- Initial $9,446 · Current $6,612 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: On or about, July 25, 2019, at 3003 N. University Drive, Sunrise, Florida 33322, employees were exposed to an electrocution hazard when the employer did not train workers on the hazards associated with the demolition work near energized electric circuits.
Recent events (2)
- — I (S) $6612
- — Z (S) $9446
1926.416 A01
- Issued
- Jan 24, 2020
- Abate by
- Feb 20, 2020
- Penalty
- Initial $13,494 · Current $10,795 Reduced
General-duty citation text
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: On or about, July 25, 2019, at 3003 N. University Drive, Sunrise, Florida 33322, employees were exposed to an electrocution hazard when the employer allowed demolition workers to remove metal wall studs and frames located near energized electric circuits without protecting workers against electric shock hazards by de-energizing and grounding, insulation or other effective means.
Recent events (2)
- — I (S) $10795
- — Z (S) $13494
1926.416 A03
- Issued
- Jan 24, 2020
- Abate by
- Feb 20, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(a)(3): Before work began, the employer did not ascertain by inquiry, direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work could bring any person, tool, or machine into pysical or electrical contact with the electric power circuit: On or about, July 25, 2019, at 3003 N. University Drive, Sunrise, Florida 33322, employees were exposed to an electrocution hazard when the employer did not locate, identify and protect employees from the electrical hazard associated with the energized wires.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238910)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344184130.