Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BILLINGS CLEANERS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BILLINGS CLEANERS, INC. in 224 WEST SQUANTUM STREET, QUINCY, MA 02171 (NAICS 812320). OSHA activity number 344186796.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Billings Cleaners, INC. — free Get an email when a new federal OSHA severe-injury report for Billings Cleaners, INC. is published. One employer, no account, unsubscribe in one click.
Site address
224 WEST SQUANTUM STREET
City
QUINCY
State
MA
ZIP
02171
Mailing
224 WEST SQUANTUM STREET, QUINCY, MA 02171
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
812320
Employees
3
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 25, 2019
Abate by
Nov 15, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Location:  Q Press SP-201 press  The cabinet garment press pinch points were unguarded and the press continued to close after the operators hands were released from the 'start buttons'.
Recent events (1)
  • — Z (S) $0

1910.212 A05

Serious Gravity 5 2 instances 2 exposed
Issued
Sep 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level:  Location:  Wall fans, Southwest wall  The bottom of wall fans were unguarded.  They were about 5 feet above the floor.