IOWA PARK, TX —
OSHA Inspection: ROYAL ENERGY SERVICES, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ROYAL ENERGY SERVICES, LLC in 4708 FM 367 W, IOWA PARK, TX 76367 (NAICS 213112). OSHA activity number 344193099.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROYAL ENERGY SERVICES, LLC
- Site address
- 4708 FM 367 W
- City
- IOWA PARK
- State
- TX
- ZIP
- 76367
- Mailing
- 1505 PB LANE SUITE B, WICHITA FALLS, TX 76302
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 8
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.132 A
- Issued
- Aug 16, 2019
- Abate by
- Sep 16, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(a): Personal protective equipment was not used when hazards capable of causing injury and impairment were encountered. On or about July 30, 2019, and at times prior thereto, at a site located at 4708 FM 367 W., Iowa Park, Texas, Rig 129: the employer did not ensure that the employees wore personal protection equipment while engage in oil and gas drilling activities. The employees did not have on Flame-Resistant Clothing (FRCs) exposing them to flash fires.
Recent events (1)
- — Z (S) $0
1910.219 D01
- Issued
- Aug 16, 2019
- Abate by
- Sep 16, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o). On or about July 30, 2019, and at times prior thereto, at a site located at 4708 FM 367 W., Iowa Park, Texas, Rig 129: the employer did not ensure that pulleys were guarded during drilling operations. The employees were exposed to rotating pulleys and caught-in hazards.
Recent events (1)
- — Z (S) $0
1910.219 E03 I
- Issued
- Aug 16, 2019
- Abate by
- Sep 16, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o)(a). On or about July 30, 2019, and at times prior thereto, at a site located at 4708 FM 367 W., Iowa Park, Texas, Rig 129: the employer did not ensure that the belt on a rotating pulley was guarded during drilling operations. The employees were expose to rotating belt and caught-in hazards.
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 213112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344193099.