Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HENDRICKSON USA, L.L.C.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of HENDRICKSON USA, L.L.C. in 277 N. HIGH STREET, HEBRON, OH 43025 (NAICS 336330). OSHA activity number 344196126.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hendrickson USA, L.L.C. — free Get an email when a new federal OSHA severe-injury report for Hendrickson USA, L.L.C. is published. One employer, no account, unsubscribe in one click.
Site address
277 N. HIGH STREET
City
HEBRON
State
OH
ZIP
43025
Mailing
277 N. HIGH STREET, HEBRON, OH 43025
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336330
Employees
256
Ownership type
A

2 citations on file for this inspection.

1910.252 B02 III

Serious Gravity 5 1 instance 71 exposed
Issued
Sep 11, 2019
Abate by
Oct 1, 2019
Penalty
Initial $9,661 · Current $6,763 Reduced
29 CFR 1910.252(b)(2)(iii): Protection from arc welding rays. Where the work permits, the welder should be enclosed in an individual booth painted with a finish of low reflectivity such as zinc oxide (an important factor for absorbing ultraviolet radiations) and lamp black, or shall be enclosed with noncombustible screens similarly painted. Booths and screens shall permit circulation of air at floor level. Workers or other persons adjacent to the welding areas shall be protected from the rays by noncombustible or flameproof screens or shields or shall be required to wear appropriate goggles.   a. On or about July 31, 2019, in the welding area, the employer did not ensure that each welding station was isolated and protected from other work areas by noncombustible or flameproof partitions, curtains, screens, or shields or ensure the use of appropriate goggles to protect employees from the welding rays.
Recent events (2)
  • — I (S) $6762.7
  • — Z (S) $9661

1910.132 D02

Other-than-serious 1 instance 256 exposed
Issued
Sep 11, 2019
Abate by
Oct 16, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.  a. On or before July 31, 2019, the employer did not verify that the personal protective equipment hazard assessment had been performed through a written certification for workplace hazards.