HUNTSVILLE, AL —
OSHA Inspection: LG ELECTRONICS U.S.A., INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of LG ELECTRONICS U.S.A., INC. in 201 JAMES RECORD ROAD BLDG #2, HUNTSVILLE, AL 35824 (NAICS 334413). OSHA activity number 344197678.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LG ELECTRONICS U.S.A., INC.
- Site address
- 201 JAMES RECORD ROAD BLDG #2
- City
- HUNTSVILLE
- State
- AL
- ZIP
- 35824
- Mailing
- 201 JAMES RECORD RD, BLDG #2 ATTN: MR. HUNYOUNG WEE, HUNTSVILLE, AL 35824
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334413
- Employees
- 111
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C01
- Issued
- Jan 27, 2020
- Abate by
- Apr 30, 2020
- Penalty
- Initial $12,145 · Current $7,287 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) On or about 7/31/2019 - Solar Panel Production Area, a program was not developed for employees exposed to caught-in hazards when performing preventive maintenance on machinery such as, but not limited to, Tabbing machines.
Recent events (2)
- — I (S) $7287
- — Z (S) $12145
1910.212 A03 II
- Issued
- Jan 27, 2020
- Abate by
- Apr 30, 2020
- Penalty
- Initial $10,409 · Current $6,245 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: a) On or about 7/31/19 - Production Line, employees were exposed to caught-in hazards when bypassing the Safety Doors Interlock mode from the Human Machine Interface (HMI) Console on eight Tabbing Machines with the doors to the machinery in an open position.
Recent events (2)
- — I (O) $6245.4
- — Z (S) $10409
More inspections at LG Electronics U.S.A., INC.
View LG Electronics U.S.A., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 334413)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344197678.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.