UTICA, NY —
OSHA Inspection: REMET CORPORATION
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of REMET CORPORATION in 301 TURNER STREET, UTICA, NY 13501 (NAICS 325998). OSHA activity number 344200902.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REMET CORPORATION
- Site address
- 301 TURNER STREET
- City
- UTICA
- State
- NY
- ZIP
- 13501
- Mailing
- 210 COMMONS RD., UTICA, NY 13502
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325998
- Employees
- 20
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.146 G01
- Issued
- Jan 16, 2020
- Abate by
- Feb 21, 2020
- Penalty
- Initial $6,630 · Current $6,630
General-duty citation text
29 CFR 1910.146(g)(1): The employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146: a) Buffer room, On or about 8/27/19: Employees required to enter permit required confined spaces, including tank K2 and K3, were not provided with training on entry procedures including, but not limited to, lockout tagout procedures, winch and harness use and 4-gas meter use. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $6630
- — Z (S) $6630
1910.146 K02 IV
- Issued
- Jan 16, 2020
- Abate by
- Feb 21, 2020
- Penalty
- Initial $3,978 · Current $3,978
General-duty citation text
29 CFR 1910.146(k)(2)(iv): An employer whose employees have been designated to provide permit space rescue and emergency services did not ensure that affected employees practiced making permit space rescues at least once every 12 months: a) Buffer room, On or about 8/27/19: Affected employees for permit required confined space entries into K2 and K3 paraffin tanks were not provided with permit space rescue drills once every 12 months. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $3978
- — Z (S) $3978
1910.147 C04 I
- Issued
- Jan 16, 2020
- Abate by
- Feb 6, 2020
- Penalty
- Initial $6,630 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Buffer room area, on or about 7/30/19: There were no written lockout/tagout procedures for employees performing servicing and maintenance on tank K2 and tank K3. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $6630
1910.303 G01
- Issued
- Jan 16, 2020
- Penalty
- Initial $5,304 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) Buffer room, on or about 10/21/19: Two 208 volt electrical disconnect switches labeled LP-SC and LP-SA and a 440 volt circuit breaker panel labeled LP-SB were blocked by stored parts and boxes.
Recent events (2)
- — I (O) $0
- — Z (S) $5304
1910.305 E01
- Issued
- Jan 16, 2020
- Abate by
- Feb 21, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed to prevent moisture or water from entering and accumulating within the enclosures: a) Flake room, on or about 10/21/19: The 480 volt panel box for operation of flaking room machine and conveyor was not placed in a location to protect it against contact with water overspray from power washing operations. Abatement certification must be submitted for this item
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at Remet Corporation
View Remet Corporation's full OSHA safety record →
More inspections in this industry (NAICS 325998)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344200902.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.