Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SECURE ROOFING INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SECURE ROOFING INC. in 185 VERONICA PLACE, BROOKLYN, NY 11226 (NAICS 238350). OSHA activity number 344202460.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Secure Roofing INC. — free Get an email when a new federal OSHA severe-injury report for Secure Roofing INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SECURE ROOFING INC.
Site address
185 VERONICA PLACE
City
BROOKLYN
State
NY
ZIP
11226
Mailing
173 WOODPOINT RD, BROOKLYN, NY 11211
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
43
Ownership type
A

5 citations on file for this inspection.

1926.451 C02 II

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 31, 2020
Penalty
Initial $6,748 · Current $3,363 Reduced
29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units:    a) The Pump Jack scaffold pole was placed on top of a 10 inch high stack of wood to add height. Four employees on the scaffold at 25 ft elevation were exposed to scaffold collapse/ unstable scaffold hazard.     Location: 185 Veronica Place, Brooklyn NY    On or about 8/1/2019     NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (3)
  • — F (S) $3362.5
  • — C (S) $6748
  • — Z (S) $6748

1926.451 F03

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 31, 2020
Penalty
Initial $6,747 · Current $3,363 Reduced
29 CFR 1926.451(f)(3):  Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift,  and after any occurrence which could affect a scaffolds structural integrity:    a) The employer did not have a competent person inspect and ensure the 40 ft tall pump jack scaffold is safe for use; the scaffold was unstable due to insufficient bracing. Four employees on the scaffold at 25 ft elevation were exposed to scaffold collapse/ unstable scaffold hazard.     Location: 185 Veronica Place, Brooklyn NY    On or about 8/1/2019    NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (3)
  • — F (S) $3362.5
  • — C (S) $6747
  • — Z (S) $6747

1926.452 J02

Serious Gravity 5 4 instances 4 exposed
Issued
Jan 31, 2020
Penalty
Initial $6,747 · Current $3,363 Reduced
29 CFR 1926.452(j)(2):  Pump Jack scaffold poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled:     a) The 40 ft tall pump jack scaffold poles only were braced at the top of the 40 ft tall poles; scaffold was swaying excessively. Four employees on the scaffold at 25 ft elevation were exposed to scaffold collapse/ unstable scaffold hazard.     Location: 185 Veronica Place, Brooklyn NY    On or about 8/1/2019    NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (3)
  • — F (S) $3362.5
  • — C (S) $6747
  • — Z (S) $6747

1926.452 J03

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 31, 2020
Penalty
Initial $6,747 · Current $0 Reduced
29 CFR 1926.452(j)(3): When guardrails are used for fall protection, a workbench was used as the toprail which did not meet all the (guardrail) requirements in paragraphs (g)(4)(ii), (vii), (viii), and (xiii) of 1926.451:     a) The pump jack scaffold had an incomplete guardrail/ workbench; there was a 10 ft long gap where there was no guardrail or workbench. Four employees on the scaffold at 25 ft elevation were exposed to unsafe scaffold/ fall hazard.     Location: 185 Veronica Place, Brooklyn NY    On or about 8/1/2019    NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (3)
  • — F (S) $0
  • — C (S) $6747
  • — Z (S) $6747

1926.454 C

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 31, 2020
Penalty
Initial $6,747 · Current $3,363 Reduced
29 CFR 1926.454(c):  Retraining was not provided when the employer has reason to believe the employee lacks the skill or understanding needed for safe work involving the erection, use or dismantling of scaffolds:    a) Employer did not ensure employees who erect and use pump jack scaffolds are trained to ensure the scaffold will remain braced and stable when employer is installing vinyl siding; four employees on the scaffold at 25 ft elevation were exposed to unsafe scaffold, scaffold collapse hazard.    Location: 185 Veronica Place, Brooklyn NY    On or about 8/1/2019    NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (3)
  • — F (S) $3362.5
  • — C (S) $6747
  • — Z (S) $6747

View Secure Roofing INC.'s full OSHA safety record →