CHICKASHA, OK ·
OSHA Inspection: OPTUM ENERGY SOLUTIONS, L.L.C.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of OPTUM ENERGY SOLUTIONS, L.L.C. in 2500 HIGHWAY 62 WEST, CHICKASHA, OK 73018 (NAICS 325998). OSHA activity number 344202569.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OPTUM ENERGY SOLUTIONS, L.L.C.
- Site address
- 2500 HIGHWAY 62 WEST
- City
- CHICKASHA
- State
- OK
- ZIP
- 73018
- Mailing
- 2500 HIGHWAY 62 WEST, CHICKASHA, OK 73018
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325998
- Employees
- 71
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jan 21, 2020
- Abate by
- Jan 29, 2020
- Penalty
- Initial $13,494 · Current $13,494
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about July 27 2019 at the LiquidPower Specialty Products Inc. (LSPI) facility, the employer did not develop, document, or use procedures to ensure the control of hazardous energy during servicing of a conveyor. Employees were exposed to caught-in hazards.
Recent events (1)
- · Z (S) $13494
1910.147 F01 II
- Issued
- Jan 21, 2020
- Abate by
- Jan 23, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(f)(1)(ii): When lockout or tagout devices temporarily were removed from the energy isolating device and the machine or equipment was energized to test or position the machine, the employees were not removed from the machine or equipment area in accordance to the paragraph (e)(2): On or about July 27 2019 at the LiquidPower Specialty Products Inc. (LSPI) facility, the employer did remove employees from the immediate area of a mill that was locked out, then re-energized for testing/debris removal. Employees were exposed to caught-in hazards.