Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMAZON.COM SERVICES, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of AMAZON.COM SERVICES, INC. in 4800 HIGHLANDS PARKWAY, SMYRNA, GA 30082 (NAICS 493110). OSHA activity number 344207626.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Amazon.Com Services, INC. — free Get an email when a new federal OSHA severe-injury report for Amazon.Com Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4800 HIGHLANDS PARKWAY
City
SMYRNA
State
GA
ZIP
30082
Mailing
4800 HIGHLANDS PARKWAY SE, SMYRNA, GA 30082
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
1080
Ownership type
A

6 citations on file for this inspection.

1910.157 C01

Deleted Other-than-serious 1 instance 5 exposed
Issued
Feb 3, 2020
Abate by
Feb 21, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a.  Sort Desk: On or about August 6, 2019, and at times prior, the employer exposed employees to smoke inhalation hazards, in that the employer did not ensure that the fire extinguisher at the sort desk was mounted to facilitate access for voluntary use in the event of a fire.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 C04

Deleted Other-than-serious 1 instance 5 exposed
Issued
Feb 3, 2020
Abate by
Feb 21, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition:  a.  Sort Desk: On or about August 6, 2019, and at times prior, the employer exposed employees to smoke inhalation hazards, in that the employer did not ensure that the fire extinguisher at the sort desk was maintained in a fully charged and operable condition.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E02

Deleted Other-than-serious 1 instance 5 exposed
Issued
Feb 3, 2020
Abate by
Feb 21, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  a.  Sort Desk: On or about August 6, 2019, and at times prior, the employer exposed employees to smoke inhalation hazards, in that the employer did not ensure that the fire extinguisher at the sort desk was visually inspected at least monthly.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.38 E

Other-than-serious 1 instance 33 exposed
Issued
Feb 3, 2020
Abate by
Mar 16, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.38(e):     Training. An employer must designate and train employees to assist in a safe and orderly evacuation of other employees.    a. Warehouse Area: On or about August 6, 2019, and at times prior, the employer exposed employees to smoke inhalation hazards, in that information was not provided to employees to familiarize them with the hazards of incipient stage fire fighting and the general principles of fire extinguisher use where fire extinguishers were available.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B02

Other-than-serious 3 instances 33 exposed
Issued
Feb 3, 2020
Abate by
Mar 16, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a.  Warehouse, PCB1-2:  On or about August 6, 2019 and at times prior, the employer exposed employees to electrical hazards, in that an Underwriter's Laboratories listed, Staples relocatable power tap used to provide electricity to a floor fan was not plugged directly into a branch circuit receptacle but was plugged into an extension cord which was plugged into a branch circuit receptacle.     b.  Warehouse, Sort Desk:  On or about August 6, 2019 and at times prior, the employer exposed employees to electrical hazards, in that an Underwriter's Laboratories listed, Staples relocatable power tap used to provide electricity to a Brother printer, a Motorola battery charger and a  Symbol battery charger was not plugged directly into a branch circuit receptacle but was plugged into an extension cord which was plugged into a branch circuit receptacle.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV D

Deleted Other-than-serious 2 instances 12 exposed
Issued
Feb 3, 2020
Abate by
Feb 21, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(D): Where not specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords were used where attached to building surfaces:  a.  Warehouse, JARS TD Inc work station:  On or about August 6, 2019 and at times prior, the employer exposed employees of JARS TD Inc to electrical hazards, in that Amazon.com Services, Inc. provided JARS TD Inc with a work station having insufficient receptacles for needed equipment then permitted the ongoing use of electrical cords attached to surfaces with cable ties to provide electrical power for laptop computers, a printer and battery chargers.  b.  Warehouse, Express Parcel Service work station:  On or about August 6, 2019 and at times prior, the employer exposed employees of EXPRESS PARCEL SERVICE LLC dba Express Parcel Service to electrical hazards, in that Amazon.com Services, Inc. provided Express Parcel Service with a work station having insufficient receptacles for needed equipment then permitted the ongoing use of electrical cords attached to surfaces with plastic cable ties to provide power to laptop computers, a printer and battery chargers.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Amazon.Com Services, INC.'s full OSHA safety record →