LACONIA, NH —
OSHA Inspection: SANITARY DRY CLEANERS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SANITARY DRY CLEANERS in 552 UNION AVE., LACONIA, NH 03246 (NAICS 812320). OSHA activity number 344207857.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SANITARY DRY CLEANERS
- Site address
- 552 UNION AVE.
- City
- LACONIA
- State
- NH
- ZIP
- 03246
- Mailing
- 552 UNION AVE., LACONIA, NH 03246
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 812320
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1903.19 C01
- Issued
- Nov 15, 2019
- Abate by
- Jan 6, 2020
- Penalty
- Initial $319 · Current $319
General-duty citation text
29 CFR 1903.19(c)(1): Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section: a. The employer did not furnish the abatement required for citations issued within 10 calendar days for Citation 1 Item 1, nor did they respond to the progress report letter sent October 28, 2019.
Recent events (1)
- — Z (O) $319
1910.132 A
- Issued
- Sep 26, 2019
- Abate by
- Oct 2, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact: Facility - Protective barriers were not maintained on the steam pipes to prevent physical contact.
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 812320)
More inspections in NH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344207857.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.