ARMOREL, AR —
OSHA Inspection: LEXICON, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LEXICON, INC. in 3859 N. COUNTY RD 919, ARMOREL, AR 72310 (NAICS 332312). OSHA activity number 344212824.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LEXICON, INC.
- Site address
- 3859 N. COUNTY RD 919
- City
- ARMOREL
- State
- AR
- ZIP
- 72310
- Mailing
- 3859 N. COUNTY RD 919, ARMOREL, AR 72310
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 25
- Ownership type
- A
Citations
19 citations on file for this inspection.
1910.212 A05
- Issued
- Feb 4, 2020
- Abate by
- Feb 12, 2020
- Penalty
- Initial $8,675 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: On or about August 5, 2019, a Schueck Steel made fan with screen openings of approximately 1-inch by 2-inches was used on the floor of Fab 2.
Recent events (3)
- — F (S) $0
- — C (S) $8675
- — Z (S) $8675
1910.252 B02 III
- Issued
- Feb 4, 2020
- Abate by
- Feb 19, 2020
- Penalty
- Initial $10,409 · Current $0 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: On or about August 5, 2019, the employer did not ensure that welding stations in the following locations were adequately enclosed by noncombustible or flame-proof screens: a. The Fab 1 shop welding stations. b. The Fab 2 shop welding stations.
Recent events (3)
- — F (S) $0
- — C (S) $10409
- — Z (S) $10409
1910.303 B01 VIII
- Issued
- Feb 4, 2020
- Abate by
- Aug 26, 2022
- Penalty
- Initial $10,409 · Current $5,205 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(viii): Electrical equipment was not free from recognized hazards based on other factors that contribute to the practical safeguarding of persons using or likely to come in contact with the equipment: West wall side in Fab 2 workshop - On or about August 5, 2019, employees were utilizing the Geka Iron-maker Hydracrop 110/A , with two broken emergency stop buttons that had not been repaired or replaced.
Recent events (3)
- — F (S) $5204.5
- — C (S) $10409
- — Z (S) $10409
1910.132 A
- Issued
- Feb 4, 2020
- Abate by
- Feb 14, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not maintained in a sanitary and reliable condition: On or about August 5, 2019: a. In Fab 1 shop, green jackets were stored on a knife switch on the west wall and work gloves and safety harnesses lying on the floor on the east side. b. In Fab 2 shop, work gloves were stored on Geka Hydracrop 110/A.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.304 F01 VIII
- Issued
- Feb 4, 2020
- Abate by
- Feb 19, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(f)(1)(viii): Circuit breakers used as switches in 120-volt and 277-volt, fluorescent lighting circuits were not listed and marked "SWD." On or about August 5, 2019 and times prior, the employer used circuit breakers that were not listed and marked "SWD" as a light switches in the following locations: a. On the southwest corner of Fab 1 workshop. b. On the east wall in Fab 2 workshop.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.22 A01
- Issued
- Feb 4, 2020
- Abate by
- Aug 26, 2022
- Penalty
- Initial $11,566 · Current $5,783 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition: On or about August 5, 2019 and times prior, the employer did not keep the following places of employment in a clean, orderly, and sanitary condition: a. The east and west sides of Fab 1 had equipment and material such as but not limited to, extension cords, taped welding machine cords, green jackets, and pieces of metal, exposing employees to trip and fall hazards. b. The walking and working surface in Fab 2 had material and equipment such as but not limited to, sheets of metal, metal pipe, fans, and portable fire extinguishers placed on the floor, exposing employees to trip and fall hazards.
Recent events (3)
- — F (O) $5783
- — C (S) $11566
- — Z (S) $11566
1910.22 A02
- Issued
- Feb 4, 2020
- Abate by
- Aug 26, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(2): The floor of each workroom was not maintained in a clean and, to the extent feasible, in a dry condition: On or about August 5, 2019 in Fab 2, water was permitted to accumulate on the floor by Geka Iron-worker Hydracrop 110/A, exposing employees to slip and fall hazards.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
1910.303 G01 I
- Issued
- Feb 4, 2020
- Abate by
- Aug 26, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(i): Work space was less than 30 inches wide in front of electric equipment operating at 600 volts, nominal, or less: On or about August 5, 2019 and times prior, the employer did not ensure that the following electrical equipment were not blocked/obstructed by items in the workplace: a. The electrical disconnect and circuit breaker boxes in Fab 1 shop that were blocked by extension cords, welding cords, Miller and Lincoln Electric welders, handheld radial Skilsaw, a green jacket obstructing a knife switch, pieces of metals, metal pole, clamping tools, fans, and pieces of wooden blocks. b. The electrical disconnect and circuit breaker boxes in Fab 2 shop on the west wall were blocked by a pallet jack, trash buckets, pieces of wood, argon cylinder, shovel, and metal welding table.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
1910.37 B02
- Issued
- Feb 4, 2020
- Abate by
- Aug 26, 2022
- Penalty
- Initial $8,675 · Current $8,675
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": On or about August 5, 2019 and times prior, the employer did not ensure that each exit door in the following locations were legibly marked with a sign reading "Exit." a. The doors on the east and west walls in Fab 2. b. The paint booth door on the east wall.
Recent events (3)
- — F (O) $8675
- — C (S) $8675
- — Z (S) $8675
1910.145 E02
- Issued
- Feb 4, 2020
- Abate by
- Aug 26, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.145(e)(2): The wording of the sign was not accurate in fact. On or about August 5, 2019, an "Exit" sign was installed on the south wall in Fab 2 shop above where a door used to be located, but was no longer an exit.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
1910.110 F06 II
- Issued
- Feb 4, 2020
- Abate by
- Aug 26, 2022
- Penalty
- Initial $6,940 · Current $6,940
General-duty citation text
29 CFR 1910.110(f)(6)(ii): Containers were not stored in a suitable enclosure or otherwise protected against tampering. On or about August 5, 2019, LP gas cylinders were stored on the ground and not enclosed or otherwise protected from tampering.
Recent events (3)
- — F (O) $6940
- — C (S) $6940
- — Z (S) $6940
1910.253 B04 III
- Issued
- Feb 4, 2020
- Abate by
- Aug 26, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: On or about August 5, 2019 and times prior thereto, the employer did not separate oxygen cylinders from fuel-gas cylinders such as but not limited to acetylene, LP gas, and propane cylinders during storage on the south side of Fab 2. These compressed cylinders were stored less than five feet from each other with no barriers.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
1910.157 C01
- Issued
- Feb 4, 2020
- Abate by
- Aug 26, 2022
- Penalty
- Initial $10,409 · Current $0 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: On or about August 5, 2019, portable fire extinguishers were stored on the floor and/or blocked when mounted in the workplace as follows: a. In Fab 1 shop on both the east and west walls by equipment and materials such as, but not limited to welders, dollies, trash cans, extension cords, pieces of metal and wood, and compressed gas cylinders. b. In Fab 2 shop by equipment and materials such as welding electrodes, extension cords, and pieces of metal pipe.
Recent events (3)
- — F (O) $0
- — C (S) $10409
- — Z (S) $10409
1910.134 C01
- Issued
- Feb 4, 2020
- Abate by
- Aug 26, 2022
- Penalty
- Initial $5,205 · Current $2,603 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: On or about August 5, 2019, employees were required to wear half mask facepiece respirators in the paint booth. The employer's written program was not implemented.
Recent events (3)
- — F (O) $2602.5
- — C (S) $5205
- — Z (S) $5205
1910.1200 J02 II
- Issued
- Feb 4, 2020
- Abate by
- Aug 26, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(j)(2)(ii): The employer did not update their written hazard communication program required by paragraph (h)(1) by June 1, 2016 to reflect changes in labeling and safety data sheets. On or about August 5, 2019 and times prior, the employer had not updated the hazard communication program that was last revised on July 1, 2004.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.303 F02
- Issued
- Feb 4, 2020
- Abate by
- Aug 26, 2022
- Penalty
- Initial $12,145 · Current $6,073 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: On or about August 5, 2019, the employer did not label the following electrical equipment: a. East and west walls of Fab 1 shop - The heavy duty disconnect and circuit breaker cabinets b. Fab 2 shop - The heavy duty disconnect and circuit breaker cabinets
Recent events (3)
- — F (O) $6072.5
- — C (S) $12145
- — Z (S) $12145
1910.305 B01 II
- Issued
- Feb 4, 2020
- Abate by
- Aug 26, 2022
- Penalty
- Initial $6,940 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about August 8, 2018 and times prior, the employer used circuit breaker cabinets with unused openings in the following locations: a. Circuit breaker cabinet on the east wall of Fab 1 had at least one unused opening on the front top side of the cabinet. b. Circuit breaker cabinet on the east wall in Fab 2 had an unused opening on the side of the cabinet. c. Circuit breaker cabinet on the west wall in Fab 2 had an unused opening on the sides of the electrical cabinets, exposing employees to electrical hazards.
Recent events (3)
- — F (O) $0
- — C (S) $6940
- — Z (S) $6940
1910.305 G01 IV A
- Issued
- Feb 4, 2020
- Abate by
- Aug 26, 2022
- Penalty
- Initial $10,409 · Current $5,205 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about August 5, 2019 and times prior, the employer used flexible cords in the place of fixed wiring in the following areas: - a. On the east wall, west wall, and floor of Fab 1 shop where extension cords were used for more than 90 days to power Americraft industrial fans and fluorescent light fixtures. b. On the east wall, west wall, and shop floor of Fab 2 where extension cords were used for more than 90 days to power industrial fans on the floor and the wall exhaust fans.
Recent events (3)
- — F (O) $5204.5
- — C (S) $10409
- — Z (S) $10409
1910.334 A02 II
- Issued
- Feb 4, 2020
- Abate by
- Aug 26, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: On or about August 5, 2019: a. Miller welder in Fab 1, cord was repaired with electric tape. b. The foot pedal of the Geka Iron-worker Hydracrop 110/A in Fab 2 was damaged and lying in a puddle of water. c. Extension cord providing power to the fan on the southwest floor of Fab 2 was repaired with electric tape.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
More inspections at Lexicon, INC.
View Lexicon, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in AR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344212824.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.