Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: KINTER CONSTRUCTION, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KINTER CONSTRUCTION, INC. in 846 E. PIKES PEAK AVE, COLORADO SPRINGS, CO 80903 (NAICS 238130). OSHA activity number 344213202.

Watch Kinter Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Kinter Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
846 E. PIKES PEAK AVE
City
COLORADO SPRINGS
State
CO
ZIP
80903
Mailing
1098 GARLOCK LANE, COLORADO SPRINGS, CO 80918
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

6 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1705.00 · Current $1000.00 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    a)  846 E. Pikes Peak Ave, Colorado Springs CO 80903: On or about August 6, 2019, and at times prior, employees were exposed to struck by hazards while working below a scaffold without wearing hard hats.  Employees were installing framework for an elevator while another employee worked on a higher level of the scaffold.  None of the employees working on lower levels were wearing hard hats.    Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1705

1926.102 A01

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee use appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors or potentially injurious light radiation:  a)  846 E. Pikes Peak Ave, Colorado Springs CO 80903:  On or about August 6, 2019, and at times prior, employees were not wearing eye protection while exposed to eye hazards.  Employees were using pneumatic nail guns to install the framework for an elevator shaft and were not wearing safety glasses.  Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 F07

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1705.00 · Current $1000.00 Reduced
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person:    a) 846 E. Pikes Peak Ave, Colorado Springs CO 80903:  On or about August 6, 2019, and at times prior, scaffolds were altered while not under the supervision and direction of a competent person.  Employees were exposed to struck by or fall hazards while using a tubular welded scaffold which had been altered after installation by a worker who was not a competent person.    Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1705

1926.451 E01

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access:   a)  846 E. Pikes Peak Ave, Colorado Springs CO 80903:  On or about August 6, 2019, and at times prior, employees were exposed to fall hazards while accessing scaffold platforms more than 2 feet above a point of access.  Employees were using crossbraces as a means of access for scaffold platforms approximately 15 feet above the ground level.  Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G04

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(4): Guardrail systems installed to meet the requirements of this section did not comply with the provisions listed in subparagraphs (i) through (xv) of this paragraph:  a)  846 E. Pikes Peak Ave, Colorado Springs CO 80903:  On or about August 6, 2019, and at times prior, employees were exposed to fall hazards due to guardrails not complying with the provisions in 29 CFR 1926.451(g)(i)-(xv).  The guardrails were incomplete or missing on the third level platform.  There were no midrails installed on the section of the platform parallel to the building and no guardrails on the left upper corner perpendicular to the building, exposing employees to fall hazards approximately 15 feet above lower levels.  Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 H01

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(h)(1): Each employee on a scaffold was not provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects.  For falling objects too large, heavy or massive to be contained or deflected, the employer did not place and secure such potential falling objects away from the edge of the surface from which they could fall:  a)  846 E. Pikes Peak Ave, Colorado Springs CO 80903:  On or about August 6, 2019, and at times prior, employees were exposed to struck by hazards due to lack of toeboards, screens, or other systems to catch or deflect falling objects.  Employees were working on a scaffold with three levels and none of the levels had protection from falling objects installed.    Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344213202.