ALPHARETTA, GA —
OSHA Inspection: R&B EXTERIORS SOLUTIONS, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of R&B EXTERIORS SOLUTIONS, LLC in (LOT #84) 440 ELLIS AVE., ALPHARETTA, GA 30009 (NAICS 238160). OSHA activity number 344221379.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- R&B EXTERIORS SOLUTIONS, LLC
- Site address
- (LOT #84) 440 ELLIS AVE.
- City
- ALPHARETTA
- State
- GA
- ZIP
- 30009
- Mailing
- 2102 MLK JR. BLVD., GAINESVILLE, GA 30501
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 10
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Dec 2, 2019
- Penalty
- Initial $3,978 · Current $3,978
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: (a) New residential construction located on Lot #84, Rear deck porch roof: On or about 08/09/2019, and at times prior, the employer exposed employees to falls of 22-feet, 6-inches to the lower level, in that fall protection was not provided to employees installing metal roofing panels on a 4/12 pitched roof.
Recent events (3)
- — A (S) $3978
- — I (S) $2386.8
- — Z (S) $3978
1926.1053 B01
- Issued
- Dec 2, 2019
- Penalty
- Initial $2,842 · Current $2,842
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) New residential construction located on Lot #84, Rear deck porch roof: On or about 08/09/2019, and at times prior, the employer exposed employees to falls of 22-feet, 6-inches to the lower level, in that the ladder used to access the roof was not extended at least 3-feet and/or secured to the structure to allow for safe access on and off the roof. The ladder used to access the roof did not reach the eave.
Recent events (3)
- — A (S) $2842
- — I (S) $1705.2
- — Z (S) $2842
More inspections in this industry (NAICS 238160)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344221379.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.