Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BOLTON CONCRETE PRODUCTS INCORPORATED

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BOLTON CONCRETE PRODUCTS INCORPORATED in 2234 MCFARLAND AVE, ROSSVILLE, GA 30741 (NAICS 339995). OSHA activity number 344228648.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bolton Concrete Products Incorporated — free Get an email when a new federal OSHA severe-injury report for Bolton Concrete Products Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
2234 MCFARLAND AVE
City
ROSSVILLE
State
GA
ZIP
30741
Mailing
P.O. BOX 869, JOHNSON CITY, TN 37605
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339995
Employees
1
Ownership type
A

7 citations on file for this inspection.

1910.179 J02

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 15, 2020
Penalty
Initial $3,031 · Current $1,819 Reduced
29 CFR 1910.179(j)(2): Frequent inspection. The following items shall be inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections. All deficiencies such as listed shall be carefully examined and determination made as to whether they constitute a safety hazard:  a) Warehouse: On or about August 13, 2019, and at times prior, the employer exposed employees to struck-by and crushing hazards while moving burial vaults, in that an overhead crane (Konecranes Model CLX10C42200 Serial Number 10305145) was not being inspected frequently.
Recent events (2)
  • — I (S) $1818.6
  • — Z (S) $3031

1910.179 J03

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 15, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.179(j)(3): Periodic inspection. Complete inspections of the crane shall be performed at intervals as generally defined in paragraph (j)(1)(ii)(b) of this section, depending upon its activity, severity of service, and environment, or as specifically indicated below. These inspections shall include the requirements of paragraph (j)(2) of this section and in addition, the following items. Any deficiencies such as listed shall be carefully examined and determination made as to whether they constitute a safety hazard:  a) Warehouse: On or about August 13, 2019, and at times prior, the employer exposed employees to struck-by and crushing hazards while moving burial vaults, in that an overhead crane (Konecranes Model CLX10C42200 Serial Number 10305145) has never been completely inspected.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 B02

Other-than-serious 1 instance 1 exposed
Issued
Jan 15, 2020
Abate by
Feb 11, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit must be clearly visible and marked by a sign reading "Exit."  a) South Wall. Warehouse: On or about August 13, 2019, and at times prior, the employer exposed employees to fire hazards in that a Fire Exit was not marked above the exit door in case of a fire emergency.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.101 B

Other-than-serious 1 instance 1 exposed
Issued
Jan 15, 2020
Abate by
Feb 11, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.101(b): "Compressed gases." The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in Sec. 1910.6. Section 3.3.1 of the CGA Pamphlet P-1-1965 refers to storing cylinders in accordance with CGA and NFPA standards The CGA Pamphlet P-1-1991 Section 3.7.4.1 states that "All compressed gas cylinders in service or in storage shall be secured to prevent from falling."  a) Warehouse: On or about August 13, 2019, and at times prior, the employer exposed employees to struck-by hazards, in that an unsecured propane tank was stored in the warehouse.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 1 exposed
Issued
Jan 15, 2020
Abate by
Feb 11, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program that included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):  a) Warehouse: On or about August 13, 2019, and at times prior, the employer exposed employees to chemical hazards, in that a written hazard communication program was not developed for employees using chemicals, such as, but not limited to: Butyl, Quick Dry Bronzing Fluid, and paint.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 G01

Other-than-serious 1 instance 1 exposed
Issued
Jan 15, 2020
Abate by
Feb 11, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use  a) Warehouse: On or about August 13, 2019, and at times prior, the employer exposed employees to chemical hazards, in that a safety data sheet was not available for employees using chemicals, such as, but not limited to: Butyl, Quick Dry Bronzing Fluid, and paint.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 1 exposed
Issued
Jan 15, 2020
Abate by
Feb 11, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) Warehouse: On or about August 13, 2019, and at times prior, the employer exposed employees to chemical hazards, in that training was not provided to employees using chemicals, such as, but not limited to: Butyl, Quick Dry Bronzing Fluid, and paint.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Bolton Concrete Products Incorporated's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344228648.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.