SCOTTSBORO, AL —
OSHA Inspection: HEAT TRANSFER PRODUCTS GROUP, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HEAT TRANSFER PRODUCTS GROUP, LLC in 201 THOMAS FRENCH DRIVE, SCOTTSBORO, AL 35769 (NAICS 333415). OSHA activity number 344230370.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HEAT TRANSFER PRODUCTS GROUP, LLC
- Site address
- 201 THOMAS FRENCH DRIVE
- City
- SCOTTSBORO
- State
- AL
- ZIP
- 35769
- Mailing
- 201 THOMAS FRENCH DRIVE, SCOTTSBORO, AL 35769
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333415
- Employees
- 364
- Ownership type
- A
Citations
10 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 11, 2019
- Penalty
- Initial $6,440 · Current $4,508 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by hazards: (a) On or about August 12, 2019 - Rack location on aisle 14, employees were exposed to struck-by hazards when damaged racks were permitted to be used for material storage.
Recent events (2)
- — I (S) $4508
- — Z (S) $6440
1910.178 L01 I
- Issued
- Dec 11, 2019
- Abate by
- Jan 8, 2020
- Penalty
- Initial $7,577 · Current $5,304 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): (a) On or about August 12, 2019 - Production area, employees were exposed to struck-by hazards when temporary employee(s) had not been trained and evaluated prior to operating powered industrial trucks such as, but not limited to, the Hyster standup forklift.
Recent events (2)
- — I (S) $5303.9
- — Z (S) $7577
1910.178 L03 I C
- Issued
- Dec 11, 2019
- Abate by
- Jan 8, 2020
- Penalty
- Initial $11,366 · Current $7,956 Reduced
General-duty citation text
29 CFR 1910.178(l)(3)(i)(C): Powered industrial truck operators did not receive initial training on truck controls and instrumentation where they were located, what they did, and how they worked: (a) On or about August 02, 2019 - Production area, employees were exposed to struck-by hazards when powered industrial truck training did not include information specific to standup forklifts controls such as, but not limited to, how to stop the standup forklift by the use of plugging, how long it takes for the forklift to stop using plugging, how long it takes the forklift to stop by taking the left foot off of the brake spot on the floor, how long it takes to stop the forklift when activating the red power disconnect switch, and recognition that an unloaded truck will tip over to the side easier than a loaded truck with its load in the lowered position.
Recent events (2)
- — I (S) $7956.2
- — Z (S) $11366
1910.178 L03 II E
- Issued
- Dec 11, 2019
- Abate by
- Jan 8, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(3)(ii)(E): Powered industrial truck operators did not receive initial training on narrow aisles and other restricted places where the vehicle would be operated: (a) On or about August 12, 2019 - Warehousing/production areas, employees were exposed to struck-by hazards when standup powered industrial truck training did not include information specific to narrow/restricted places such as, but not limited to, the narrow PMZ gate and the aisle in front of the brazing department. Training such as, but not limited to, how to approach the narrow site, how to enter the narrow site, and whether entry should be made with forks leading or trailing was not provided.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L04 II B
- Issued
- Dec 11, 2019
- Abate by
- Jan 8, 2020
- Penalty
- Initial $7,577 · Current $5,304 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(ii)(B): Refresher training in relevant topics was not provided to the operator when the operator had been involved in an accident or near-miss incident: (a) On or about August 12, 2019 - Production area, employees were exposed to struck-by hazards when employees were not re-evaluated or re-trained after an accident or near-miss incident including incidents such as, but not limited to, hitting the narrow PMZ chain link gate.
Recent events (2)
- — I (S) $5303.9
- — Z (S) $7577
1910.178 L04 II C
- Issued
- Dec 11, 2019
- Abate by
- Jan 8, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(ii)(C): Refresher training in relevant topics was not provided to the operator when the operator had received an evaluation that revealed that the operator was not operating the truck safely: (a) On or about August 12, 2019 - Production area, employees were exposed to struck-by hazards when an employee was permitted to drive a standup forklift when the operator received an evaluation that revealed that the operator was not operating the truck safely.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 Q07
- Issued
- Dec 11, 2019
- Abate by
- Jan 8, 2020
- Penalty
- Initial $7,577 · Current $5,304 Reduced
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: (a) On or about August 12, 2019 - Production area, employees were exposed to struck-by hazards when employees were not verifying braking/plugging/battery power disconnect (emergency stop) before being placed in service because employees did not understand the difference in the braking systems and how to check them.
Recent events (2)
- — I (S) $5303.9
- — Z (S) $7577
1910.178 L06
- Issued
- Dec 11, 2019
- Abate by
- Jan 8, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): (a) On or about August 12, 2019 - Production area, documentation that temporary employee(s) had been trained/evaluated to operate sit-down forklifts could not be produced.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.252 B02 III
- Issued
- Dec 11, 2019
- Abate by
- Jan 8, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not required to wear appropriate goggles to protect them from the rays when noncombustible or flameproof screens or shields were not used: (a) On or about August 12, 2019 - Main aisle next to brazing stations, employees in the aisle were exposed to eye hazards when there were no protective curtains at the brazing stations.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01 I A
- Issued
- Dec 11, 2019
- Abate by
- Jan 8, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910: (a) On or about August 12, 2019 - Electrical panels on main aisle, employees were exposed to electrical hazards when the yellow guardrail to the front of the equipment was approximately 19 inches from the front of the panels.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Heat Transfer Products Group, LLC
View Heat Transfer Products Group, LLC's full OSHA safety record →
More inspections in this industry (NAICS 333415)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344230370.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.