PADUCAH, KY —
OSHA Inspection: NATIONAL MAINTENANCE & REPAIR OF KENTUCKY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NATIONAL MAINTENANCE & REPAIR OF KENTUCKY, INC. in 4350 CLARKS RIVER ROAD, PADUCAH, KY 42002 (NAICS 336611). OSHA activity number 344238712.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATIONAL MAINTENANCE & REPAIR OF KENTUCKY, INC.
- Site address
- 4350 CLARKS RIVER ROAD
- City
- PADUCAH
- State
- KY
- ZIP
- 42002
- Mailing
- P.O. BOX 3159, PADUCAH, KY 42002
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336611
- Employees
- 60
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.25 B01
- Issued
- Oct 18, 2019
- Abate by
- Nov 14, 2019
- Penalty
- Initial $10,741 · Current $7,700 Reduced
General-duty citation text
29 CFR 1910.25(b)(1): The employer did not ensure handrails, stair rail systems, and guardrail systems were provided in accordance with 29 CFR 1910.28: a) On or about August 14, 2019 on drydocks the employees were exposed to falls from heights of up to 12 feet while utilizing stairs to access vessels and the employer did not ensure unprotected sides were provided with guardrails.
Recent events (2)
- — I (S) $7700
- — Z (S) $10741
1910.303 G01 I
- Issued
- Oct 18, 2019
- Abate by
- Nov 14, 2019
- Penalty
- Initial $4,603 · Current $2,600 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i): Working space for equipment likely to require examination, adjustment, servicing, or maintenance while energized did not comply with the depth and width requirements of this subpart: a) On or about August 14, 2019 in the electrical shop employees were working near stored materials adjacent to electrical panels and the employer did not ensure stored materials were located within 3 feet of the front and within 30 inches width of the electrical panels. b) On or about August 14, 2019 in the mechanical shop employees were working near stored materials adjacent to electrical panels and the employer did not ensure stored materials were located within 3 feet of the front and within 30 inches width of the electrical panels.
Recent events (2)
- — I (O) $2600
- — Z (S) $4603
1910.304 G05
- Issued
- Oct 18, 2019
- Abate by
- Nov 14, 2019
- Penalty
- Initial $7,672 · Current $4,800 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) On or about August 14, 2019 on the captive barge employees were exposed to electrical hazards and the employer did not ensure the path to ground through flexible cords from equipment was permanent, continuous, and effective.
Recent events (2)
- — I (S) $4800
- — Z (S) $7672
1910.305 B02 I
- Issued
- Oct 18, 2019
- Abate by
- Nov 14, 2019
- Penalty
- Initial $4,603 · Current $2,600 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): In completed installations, each outlet box did not have a cover, faceplate, or fixture canopy: a) On or about August 14, 2019 in the foreman office building employees were exposed to electrical hazards and the employer did not ensure receptacles had no live parts normally exposed to employee contact.
Recent events (2)
- — I (O) $2600
- — Z (S) $4603
1915.71 H01
- Issued
- Oct 18, 2019
- Abate by
- Nov 14, 2019
- Penalty
- Initial $10,741 · Current $7,700 Reduced
General-duty citation text
29 CFR 1915.71(h)(1): Scaffolds of a type for which specifications are not contained in this section did not meet the general requirements of paragraphs (b), (i), and (j) of this section, were not in accordance with recognized principles of design and were not constructed in accordance with accepted standards covering such equipment: a) On or about August 15, 2019 aboard the M/V Tom Frasier employees were installing fire protection system from an elevated walk board while exposed to a fall hazard of 10 feet and the employer did not ensure the scaffold was in accordance with 1915.71(j)(1).
Recent events (2)
- — I (S) $7700
- — Z (S) $10741
1915.73 D
- Issued
- Oct 18, 2019
- Penalty
- Initial $9,206 · Current $6,500 Reduced
General-duty citation text
29 CFR 1915.73(d): When employees are exposed to unguarded edges of decks, platforms, flats, and similar flat surfaces, more than 5 feet above a solid surface, the edges were not guarded by adequate guardrails meeting the requirements of 1915.71(j)(1) and (2), unless the nature of the work in progress or the physical conditions prohibit the use or installation of such guardrails: a) On or about August 14, 2019 aboard the M/V Tom Frasier employees were exposed to falls of 8 foot 7 inches and the employer did not ensure edges of decks were unguarded by adequate guardrails.
Recent events (2)
- — I (S) $6500
- — Z (S) $9206
1915.87 F02 I
- Issued
- Oct 18, 2019
- Abate by
- Nov 14, 2019
- Penalty
- Initial $9,206 · Current $0 Reduced
General-duty citation text
29 CFR 1915.87(f)(2)(i): Permanent lifting bridles that enable the basket stretcher, or the equivalent, to be attached to hoisting gear capable of lifting at least 5,000 pounds (2,270 kg) were not provided: a) On or about August 14, 2019 employees working near the water are exposed to water immersion hazards and the employer did not ensure permanent lifting bridles were equipped on each basket stretcher.
Recent events (2)
- — I (S) $0
- — Z (S) $9206
1915.132 D
- Issued
- Oct 18, 2019
- Abate by
- Nov 14, 2019
- Penalty
- Initial $4,603 · Current $2,600 Reduced
General-duty citation text
29 CFR 1915.132(d): Worn or frayed electric cables were used: a) On or about August 14, 2019 on the dock employees were using electrical cords with wires exposed and the employer did not ensure work or frayed electric cables were used. b) On or about August 14, 2019 on the dock employees were using electrical cords with pinched, torn, and burned outer insulation while being suspended from metal wire and the employer did not ensure work or frayed electric cables were used.
Recent events (2)
- — I (O) $2600
- — Z (S) $4603
1915.134 A
- Issued
- Oct 18, 2019
- Penalty
- Initial $7,672 · Current $5,500 Reduced
General-duty citation text
29 CFR 1915.134(a): Floor stand and bench mounted abrasive wheels used for external grinding was not provided with safety guards (protection hoods). Safety guards were not strong enough to withstand the effect of a bursting wheel: a) On or about June 14, 2019 in the mechanical shop employees used an abrasive wheel floor grinder and the employer did not ensure safety guards were maintained in position necessary to render protection.
Recent events (2)
- — I (S) $5500
- — Z (S) $7672
1915.134 B
- Issued
- Oct 18, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1915.134(b): Floor and bench mounted grinders were not provided with work rests which are rigidly supported and readily adjustable. Such work rests were not kept a distance not to exceed 1/8 inch from the surface of the wheel: a) On or about June 14, 2019 in the mechanical shop employees used an abrasive wheel floor grinder and the employer did not ensure the work rests were maintained no more than 1/8th inch from the surface of the wheel.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV B
- Issued
- Oct 18, 2019
- Abate by
- Nov 14, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables were used where run through holes in walls, ceilings, or floors: a) On or about August 14, 2019 in the employee breakroom employees were exposed to electrical hazards and the employer did not ensure a floor fan flexible cord was not run through a hole in the wall.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 F06
- Issued
- Oct 18, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6): Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked: a) On or about August 14, 2019 near the dock access ramp employees were exposed to fire hazards from a diesel container and the employer did not ensure the container was labeled, tagged, or marked.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at National Maintenance & Repair of Kentucky, INC.
View National Maintenance & Repair of Kentucky, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336611)
More inspections in KY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344238712.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.