WIGGINS, MS —
OSHA Inspection: DUNN PAPER, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DUNN PAPER, INC. in 1321 S. MAGNOLIA, WIGGINS, MS 39577 (NAICS 322121). OSHA activity number 344238845.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DUNN PAPER, INC.
- Site address
- 1321 S. MAGNOLIA
- City
- WIGGINS
- State
- MS
- ZIP
- 39577
- Mailing
- 1321 S. MAGNOLIA, WIGGINS, MS 39577
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322121
- Employees
- 720
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C02 II
- Issued
- Oct 11, 2019
- Abate by
- Nov 6, 2019
- Penalty
- Initial $6,440 · Current $3,864 Reduced
General-duty citation text
29 CFR 1910.147(c)(2)(ii): An energy isolating device that was capable of being locked out, did not utilize a lockout device, which renderedi the machine or equipment inoperative. (a) Panel CBP-2F - On or about August 16, 2019 electrical breakers were not locked out exposing employees to electrical shock.
Recent events (2)
- — I (S) $3864
- — Z (S) $6440
1910.253 B02 II
- Issued
- Oct 11, 2019
- Abate by
- Nov 6, 2019
- Penalty
- Initial $13,260 · Current $7,956 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: (a) Rear of building by loading dock - On or about August 16, 2019 oxygen cylinders stored next to open overhead door where fork trucks operate and tanks not secure exposed employees to fire hazards.
Recent events (2)
- — I (S) $7956
- — Z (S) $13260
1910.253 B04 III
- Issued
- Oct 11, 2019
- Abate by
- Nov 6, 2019
- Penalty
- Initial $8,051 · Current $4,831 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. (a) Rear of building - On or about August 16, 2019 oxygen cylinders stored next to flammable cylinders exposed employees to fire hazards.
Recent events (2)
- — I (S) $4830.6
- — Z (S) $8051
1910.303 C
- Issued
- Oct 11, 2019
- Abate by
- Nov 6, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(c): Splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device suitable for the purpose: (a) East side of paper mill 1 - On or about August 16, 2019 the connection on the power supply was not adequately insulated exposing employees to electrical shock hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Oct 11, 2019
- Abate by
- Nov 6, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) Center wall in warehouse - On or about August 16, 2019 material stored in front of Electrical panel CBP-2F exposed employees to fire and electrical shock hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 A02
- Issued
- Oct 11, 2019
- Abate by
- Nov 6, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(2): Temporary electrical power and lighting installations of 600 volts, nominal, or less were used for purposes other than those permitted in subparagraphs (a), (b) and (c) of this paragraph. Employer used temporary electrical power for purposes, or duration in excess of, what is approved by this regulation. (A) Behind wet machine - On or about August 16, 2019 an electrical extension cord used as permanent wiring exposed employees to electrical shock hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Dunn Paper, INC.
View Dunn Paper, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 322121)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344238845.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.