Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DUNN PAPER, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DUNN PAPER, INC. in 1321 S. MAGNOLIA, WIGGINS, MS 39577 (NAICS 322121). OSHA activity number 344238845.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dunn Paper, INC. — free Get an email when a new federal OSHA severe-injury report for Dunn Paper, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
DUNN PAPER, INC.
Site address
1321 S. MAGNOLIA
City
WIGGINS
State
MS
ZIP
39577
Mailing
1321 S. MAGNOLIA, WIGGINS, MS 39577
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322121
Employees
720
Ownership type
A

6 citations on file for this inspection.

1910.147 C02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 11, 2019
Abate by
Nov 6, 2019
Penalty
Initial $6,440 · Current $3,864 Reduced
29 CFR 1910.147(c)(2)(ii): An energy isolating device that was capable of being locked out, did not utilize a lockout device, which renderedi the machine or equipment inoperative.  (a) Panel CBP-2F - On or about August 16, 2019 electrical breakers were not locked out exposing employees to electrical shock.
Recent events (2)
  • — I (S) $3864
  • — Z (S) $6440

1910.253 B02 II

Serious Gravity 10 1 instance 91 exposed
Issued
Oct 11, 2019
Abate by
Nov 6, 2019
Penalty
Initial $13,260 · Current $7,956 Reduced
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:  (a) Rear of building by loading dock - On or about August 16, 2019 oxygen cylinders stored next to open overhead door where fork trucks operate and tanks not secure exposed employees to fire hazards.
Recent events (2)
  • — I (S) $7956
  • — Z (S) $13260

1910.253 B04 III

Serious Gravity 5 1 instance 91 exposed
Issued
Oct 11, 2019
Abate by
Nov 6, 2019
Penalty
Initial $8,051 · Current $4,831 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.  (a) Rear of building - On or about August 16, 2019 oxygen cylinders stored next to flammable cylinders exposed employees to fire hazards.
Recent events (2)
  • — I (S) $4830.6
  • — Z (S) $8051

1910.303 C

Other-than-serious 1 instance 1 exposed
Issued
Oct 11, 2019
Abate by
Nov 6, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(c): Splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device suitable for the purpose:  (a) East side of paper mill 1 - On or about August 16, 2019 the connection on the power supply was not adequately insulated exposing employees to electrical shock hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 3 exposed
Issued
Oct 11, 2019
Abate by
Nov 6, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  (a) Center wall in warehouse - On or about August 16, 2019 material stored in front of Electrical panel CBP-2F exposed employees to fire and electrical shock hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 A02

Other-than-serious 1 instance 3 exposed
Issued
Oct 11, 2019
Abate by
Nov 6, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2): Temporary electrical power and lighting installations of 600 volts, nominal, or less were used for purposes other than those permitted in subparagraphs (a), (b) and (c) of this paragraph. Employer used temporary electrical power for purposes, or duration in excess of, what is approved by this regulation.   (A) Behind wet machine - On or about August 16, 2019 an electrical extension cord used as permanent wiring exposed employees to electrical shock hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Dunn Paper, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344238845.