STONE MOUNTAIN, GA —
OSHA Inspection: TOOL SYSTEMS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TOOL SYSTEMS, INC. in 2220 CENTRE PARK COURT, STONE MOUNTAIN, GA 30087 (NAICS 339999). OSHA activity number 344239082.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TOOL SYSTEMS, INC.
- Site address
- 2220 CENTRE PARK COURT
- City
- STONE MOUNTAIN
- State
- GA
- ZIP
- 30087
- Mailing
- 2220 CENTRE PARK COURT, STONE MOUNTAIN, GA 30087
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339999
- Employees
- 20
- Ownership type
- A
Citations
14 citations on file for this inspection.
1910.37 A04
- Issued
- Oct 3, 2019
- Penalty
- Initial $3,381 · Current $2,029 Reduced
General-duty citation text
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: a) Front office: On or about August 14, 2019, and at times prior to, the employer did not ensure that emergency exit lighting was provided and in working order. In case of fire or other emergency requiring evacuation, employees were exposed to entrapment, burns, and smoke inhalation hazards.
Recent events (2)
- — I (S) $2028.6
- — Z (S) $3381
1910.37 B04
- Issued
- Oct 3, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent. a) Receiving work shop area - On August 14, 2019, the employer did not post signs so as to indicate the direction of travel to the nearest exit when the exit discharge path was not immediately apparent due to product being stacked to high levels in the area.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 B06
- Issued
- Oct 3, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color: a) Front office: On or about August 14, 2019, the employer did not ensure that emergency exit signs were illuminated and in working condition. In case of fire or other emergency requiring evacuation, employees were exposed to entrapment, burns, and smoke inhalation hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.101 B
- Issued
- Oct 3, 2019
- Penalty
- Initial $5,635 · Current $3,381 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: (3.3.8 - Where caps were provided for valve protection, such caps were not kept on cylinders in storage) On or about September 2018, and at times prior to, employees were exposed to struck-by hazards where compressed gas cylinders were stored without their valve caps. Instances include, but are not limited to the following: a) Waveguide Dehydrators area: At least two (2) compress gas cylinders containing Carbon Dioxide were stored without valve caps. Employees were exposed to struck-by hazards when compressed gas cylinders used for testing equipment were stored without valve caps. b) Receiving area: A compress gas cylinders containing Carbon Dioxide were stored without valve caps. Employees were exposed to struck-by hazards when compressed gas cylinders used for testing equipment were stored without valve caps.
Recent events (2)
- — I (S) $3381
- — Z (S) $5635
1910.157 C01
- Issued
- Oct 3, 2019
- Penalty
- Initial $3,381 · Current $2,029 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: On or about August 14, 2019, employees in the Shop area were exposed to hazards associated with improperly stored fire extinguishers where the following deficiencies found included, but were not limited to: a) Shop area - Fire extinguisher was mounted and properly marked, but was blocked by computers and other equipment. b) Shop area- Fire extinguisher was not mounted, identified by signage and not mounted and left on the ground. c) Receiving exit door - Fire extinguisher was properly mounted, identified with signage, but it was blocked by boxes and other equipment.
Recent events (2)
- — I (S) $2028.6
- — Z (S) $3381
1910.157 E02
- Issued
- Oct 3, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: a) On or about August 14, 2019, throughout the facility, employees engaged in work activities associated with the production of guards were exposed to hazards associated with portable fire extinguishers that were not inspected on a monthly basis, deficiencies included, but were not limited to fire extinguishers that were not mounted or located in designated areas, blocked by equipment, and missing annual and monthly inspection tags.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 E03
- Issued
- Oct 3, 2019
- Abate by
- Oct 30, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: a) Shop - On or about August 14, 2019, the employer did not ensure that portable fire extinguishers were inspected and maintained on an annual basis as required. b) Forklift- On or about August 14, 2019, the employer did not ensure that the portable fire extinguisher were inspected when the yellow tag on the extinguisher was ripped off.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 G01
- Issued
- Oct 3, 2019
- Abate by
- Oct 30, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting: a) Shop - On or about August 14, 2019, the employer did not train employees who were expected to use the fire extinguishers in case of a fire. Employees were exposed to fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L01 I
- Issued
- Oct 3, 2019
- Penalty
- Initial $5,635 · Current $3,381 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) Shop- On or about August 14, 2019 and times prior to, employees operated the powered industrial truck to move materials including, but not limited to pallets throughout the facility. The employer did not ensure that each operator had successfully completed training and evaluation as required.
Recent events (2)
- — I (S) $3381
- — Z (S) $5635
1910.242 B
- Issued
- Oct 3, 2019
- Penalty
- Initial $9,282 · Current $5,569 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Milling Machines - On or about August 14, 2019, employees used compress air to clean metal residue from themselves, and surfaces in the area of the Milling machines. The pressure measured in excess of 80 psi, exposing employees to embolism hazards and injuries resulting from being struck by flying particles.
Recent events (2)
- — I (S) $5569.2
- — Z (S) $9282
1910.303 B02
- Issued
- Oct 3, 2019
- Penalty
- Initial $3,381 · Current $2,012 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Shop: On or about August 14, 2019, several reloadable power taps where daisy chain together to energize equipment including, but not limited to, computers, fans, cellphones and table saws exposing employees to electroshock hazards. a) Milling machines: On or about August 14, 2019, several reloadable power taps where daisy chain together to energize equipment including, but not limited to, milling machines and other equipment exposing employees to electroshock hazards.
Recent events (2)
- — I (S) $2011.6
- — Z (S) $3381
1910.305 G01 IV A
- Issued
- Oct 3, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about August 14, 2019, employees were exposed to electric shock hazards where employees used equipment receiving power from flexible cords. Instances include but are not limited to the following: a) Shop: Employees operating equipment including, but not limited to, table saws, fans and computers receiving power from a flexible cord. b) Milling machine: Employees receiving power from a flexible cord.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV D
- Issued
- Oct 3, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were attached to building surfaces: a) Shop - On or about August 14, 2019, employees were exposed to hazards associated with the use of extension cords attached to the ceiling and running across the building platform. The extension cord was used to provide power equipment including but not limited to, computers, table saw phones and other equipment used throughout the day.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Oct 3, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) Shop: On or about August 14, 2019, employees were exposed to electroshocked hazards when extensions cords were connected without strain relief and attached to the ceiling and running across the building platform. The extension cord was used to provide power equipment including but not limited to, phones and other equipment used throughout the day.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Tool Systems, INC.
View Tool Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 339999)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344239082.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.