BUFFALO, NY —
OSHA Inspection: TAPECON INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TAPECON INC. in 315 LARKIN STREET, BUFFALO, NY 14210 (NAICS 323112). OSHA activity number 344241468.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TAPECON INC.
- Site address
- 315 LARKIN STREET
- City
- BUFFALO
- State
- NY
- ZIP
- 14210
- Mailing
- 701 SENECA STREET SUITE 255, BUFFALO, NY 14210
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323112
- Employees
- 100
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.28 B07
- Issued
- Oct 8, 2019
- Abate by
- Oct 31, 2019
- Penalty
- Initial $6,630 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.28(b)(7): The employer did not ensure that each employee on a walking-working surface near an opening, including one with a chute attached, where the inside bottom edge of the opening is less than 39 inches (99 cm) above that walking-working surface and the outside bottom edge of the opening is 4 feet (1.2 m) or more above a lower level is protected from falling by the use of: 1910.28(b)(7)(i) Guardrail systems; 1910.28(b)(7)(ii) Safety net systems; 1910.28(b)(7)(iii) Travel restraint systems; or, 1910.28(b)(7)(iv) Personal fall arrest systems. a) On or about 06/10/2019; where employees were potentially exposed to falls down a 2nd floor garbage chute to the dumpster on the first floor. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $4000
- — C (S) $6630
- — Z (S) $6630
1910.106 E06 II
- Issued
- Oct 8, 2019
- Abate by
- Oct 31, 2019
- Penalty
- Initial $5,304 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 degree F (37.8 degree C), were dispensed into containers without the containers being electrically interconnected: a) On or about 08/20/2019 in the flammable storage room; where isopropyl alcohol and ethyl acetate were transferred from a 55 gallon drum to secondary containers without interconnecting the two containers. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $3500
- — C (S) $5304
- — Z (S) $5304
1910.147 C04 I
- Issued
- Oct 8, 2019
- Abate by
- Oct 31, 2019
- Penalty
- Initial $6,630 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 08/20/2019 in the Digital Printing Room; where energy control procedures were not utilized for set up operations on machines and equipment such as, but not limited to: Arpeco Tracker (slitter), unwinding slitter and die cutting machine b) On or about 08/20/2019 in the Screen Printing Room; where energy control procedures were not developed and documented for gas dryers in the screen printing room (equipment which has multiple energy sources - gas, electric, electromechanical). ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $4000
- — C (S) $6630
- — Z (S) $6630
1910.303 B07 I
- Issued
- Oct 8, 2019
- Abate by
- Oct 31, 2019
- Penalty
- Initial $6,630 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: a) On or about 08/20/2019 in the production areas; where there were missing knockouts resulting in unused openings in power panel 15 (missing knockout) and Asset #310, the mobile UV cure unit (missing knockout). ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (S) $4000
- — C (S) $6630
- — Z (S) $6630
1904.39 A02
- Issued
- Oct 8, 2019
- Penalty
- Initial $5,000 · Current $0 Reduced
General-duty citation text
29 CFR 1904.39(a)(2): The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye: a) On or about 08/20/2019; where a work-related amputation injury occurred on 06/10/2019 and the employer did not notify the Buffalo OSHA office. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (O) $0
- — C (O) $5000
- — Z (O) $5000
1910.303 B02
- Issued
- Oct 8, 2019
- Abate by
- Oct 31, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) On or about 08/20/2019 I the Digital Printing Room; where a temporary power tap (power strip) was used for a motor load (pedestal fan) and in place of fixed wiring (as an extension cord to supply power to a receptacle outlet). ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
1910.303 E01 II
- Issued
- Oct 8, 2019
- Abate by
- Oct 31, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(e)(1)(ii): Electrical equipment was used when the markings giving voltage, current, wattage, or other ratings as necessary were missing: a) On or about 08/20/2019 in the unwinding/slitter area; where Power Panel 15 was not marked to indicate the voltage in the panel. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Oct 8, 2019
- Abate by
- Oct 31, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) On or about 08/20/2019 in Flexo printing area; where an extension cord was used in place of fixed wiring to supply power to a "UV light" on FLEXO machine. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
1910.305 G01 IV B
- Issued
- Oct 8, 2019
- Abate by
- Oct 31, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv) - [1910.305(g)(1)(iv)(B): Where run through holes in walls, ceilings, or floors]: a) On or about 08/20/2019 in Flexo Converting; where two extension cords, supplying power to machines and equipment, were run through the ceiling. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Tapecon INC.
View Tapecon INC.'s full OSHA safety record →
More inspections in this industry (NAICS 323112)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344241468.