Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: CAPONE IRON CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CAPONE IRON CORPORATION in 20 TURCOTTE MEMORIAL DRIVE, ROWLEY, MA 01969 (NAICS 332312). OSHA activity number 344243860.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Capone Iron Corporation for free Get an email when a new federal OSHA severe-injury report for Capone Iron Corporation is published. One employer, no account, unsubscribe in one click.
Site address
20 TURCOTTE MEMORIAL DRIVE
City
ROWLEY
State
MA
ZIP
01969
Mailing
20 TURCOTTE MEMORIAL DRIVE, ROWLEY, MA 01969
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
60
Ownership type
Private (A)

6 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 18 exposed
Issued
Sep 17, 2019
Abate by
Nov 30, 2019
Penalty
Initial $9,282 · Current $3,500 Reduced
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section:    (a) Location - 20 Turcotte Memorial Drive, Rowley, MA:    On or about 08/19/2019, the energy control procedure for the Geka Ironworker did not contain the means to enforce compliance with the procedure and a specific statement of the intended use of procedure.
Recent events (3)
  • · F (S) $3500
  • · C (S) $9282
  • · Z (S) $9282

1910.147 C06 I A

Serious Gravity 5 1 instance 18 exposed
Issued
Sep 17, 2019
Abate by
Nov 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i)(A): The periodic inspection of the energy control procedure was not performed by an authorized employee other than the one utilizing the energy control procedure being inspected:    (a) Location - 20 Turcotte Memorial Drive, Rowley, MA:    On or about 08/19/2019, the most recent periodic inspection of the energy control procedure for the Geka Ironworker was not performed by an authorized employee other than the one utilizing the procedure.
Recent events (3)
  • · F (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.212 A03 II

Serious Gravity 5 1 instance 18 exposed
Issued
Sep 17, 2019
Abate by
Nov 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment:  (a) Location - 20 Turcotte Memorial Drive, Rowley, MA:  On or about 08/19/2019, the Geka Ironworker was not turned off or shutdown in accordance with its hazardous energy control procedure prior to an employee bypassing the machine's guarding to adjust its tooling. 29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    (a) Location - 20 Turcotte Memorial Drive, Rowley, MA:    On or about 08/19/2019, the point of operation of the punch station of the Piranha Ironworker was not safeguarded.
Recent events (3)
  • · F (S) $0
  • · C (S) $0
  • · Z (S) $0

1910.212 A01

Other-than-serious 1 instance 18 exposed
Issued
Sep 17, 2019
Abate by
Nov 30, 2019
Penalty
Initial $6,630 · Current $1,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) Location - 20 Turcotte Memorial Drive, Rowley, MA:    On or about 08/19/2019, the KEF Drill Press did not have a chuck guard.
Recent events (3)
  • · F (O) $1000
  • · C (S) $6630
  • · Z (S) $6630

1910.147 C06 II

Other-than-serious 1 instance 18 exposed
Issued
Sep 17, 2019
Abate by
Nov 30, 2019
Penalty
Initial $744 · Current $500 Reduced
29 CFR 1910.147(c)(6)(ii): The certification did not identify the employees included in the inspection and the person performing the inspection:    (a) Location - 20 Turcotte Memorial Drive, Rowley, MA:    On or about 08/19/2019, the certification of the most recent periodic inspection of the employer's hazardous energy control procedures did not identify the employees involved in the inspection and the person who performed the inspection.
Recent events (3)
  • · F (O) $500
  • · C (O) $744
  • · Z (O) $744

1910.147 C07 IV

Other-than-serious 1 instance 18 exposed
Issued
Sep 17, 2019
Abate by
Nov 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date:    (a) Location - 20 Turcotte Memorial Drive, Rowley, MA:    On or about 08/19/2019, authorized employee training under the employer's hazardous energy control program was not certified.
Recent events (3)
  • · F (O) $0
  • · C (O) $0
  • · Z (O) $0

View Capone Iron Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344243860.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.