ROWLEY, MA —
OSHA Inspection: CAPONE IRON CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CAPONE IRON CORPORATION in 20 TURCOTTE MEMORIAL DRIVE, ROWLEY, MA 01969 (NAICS 332312). OSHA activity number 344243860.
Where did this inspection happen?
- Establishment
- CAPONE IRON CORPORATION
- Site address
- 20 TURCOTTE MEMORIAL DRIVE
- City
- ROWLEY
- State
- MA
- ZIP
- 01969
- Mailing
- 20 TURCOTTE MEMORIAL DRIVE, ROWLEY, MA 01969
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 60
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $9282.00 · Current $3500.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: (a) Location - 20 Turcotte Memorial Drive, Rowley, MA: On or about 08/19/2019, the energy control procedure for the Geka Ironworker did not contain the means to enforce compliance with the procedure and a specific statement of the intended use of procedure.
Recent events (3)
- — F (S) $3500
- — C (S) $9282
- — Z (S) $9282
1910.147 C06 I A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i)(A): The periodic inspection of the energy control procedure was not performed by an authorized employee other than the one utilizing the energy control procedure being inspected: (a) Location - 20 Turcotte Memorial Drive, Rowley, MA: On or about 08/19/2019, the most recent periodic inspection of the energy control procedure for the Geka Ironworker was not performed by an authorized employee other than the one utilizing the procedure.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: (a) Location - 20 Turcotte Memorial Drive, Rowley, MA: On or about 08/19/2019, the Geka Ironworker was not turned off or shutdown in accordance with its hazardous energy control procedure prior to an employee bypassing the machine's guarding to adjust its tooling. 29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Location - 20 Turcotte Memorial Drive, Rowley, MA: On or about 08/19/2019, the point of operation of the punch station of the Piranha Ironworker was not safeguarded.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $6630.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Location - 20 Turcotte Memorial Drive, Rowley, MA: On or about 08/19/2019, the KEF Drill Press did not have a chuck guard.
Recent events (3)
- — F (O) $1000
- — C (S) $6630
- — Z (S) $6630
1910.147 C06 II
- Issued
- Abate by
- Penalty
- Initial $744.00 · Current $500.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The certification did not identify the employees included in the inspection and the person performing the inspection: (a) Location - 20 Turcotte Memorial Drive, Rowley, MA: On or about 08/19/2019, the certification of the most recent periodic inspection of the employer's hazardous energy control procedures did not identify the employees involved in the inspection and the person who performed the inspection.
Recent events (3)
- — F (O) $500
- — C (O) $744
- — Z (O) $744
1910.147 C07 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date: (a) Location - 20 Turcotte Memorial Drive, Rowley, MA: On or about 08/19/2019, authorized employee training under the employer's hazardous energy control program was not certified.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at CAPONE IRON CORPORATION
ROWLEY, MA—2012-03-09 00:00:00
CAPONE IRON CORPORATION
NEEDHAM, MA—1998-02-20 00:00:00
CAPONE IRON CORPORATION
View CAPONE IRON CORPORATION's full OSHA safety record →
More inspections in this industry (NAICS 332312)
WYOMING, MI—2026-07-16
R&M FABRICATION LLC
TRUSSVILLE, AL—2026-07-16
ALL SOUTH STEELWORX, LLC
NORTH BRANCH, MN—2026-07-15
111603 - BROWN HAWK LLC DBA NORTHERN LIGHTS STEEL FAB
VAN BUREN, AR—2026-07-14
MILLAR PARTNERS, LLC
CLANTON, AL—2026-07-14
C & S CANOPY, INC.
More inspections in MA
BELLINGHAM, MA—2026-07-16
BELLINGHAM DEPARTMENT OF PUBLIC WORKS
PLYMOUTH, MA—2026-07-15
TECH-ETCH, INC.
WESTFIELD, MA—2026-07-15
BOISE CASCADE BUILDING MATERIALS DISTRIBUTION, L.L.C.
QUINCY, MA—2026-07-15
UNITEDWOR VM CONTRACTOR CORP
FALL RIVER, MA—2026-07-15
CRESCO LABS, INC.
Source