BLACK RIVER FALLS, WI —
OSHA Inspection: FLASH4.COM, LLC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of FLASH4.COM, LLC. in 730 RED IRON ROAD, BLACK RIVER FALLS, WI 54615 (NAICS 323119). OSHA activity number 344244272.
Where did this inspection happen?
- Establishment
- FLASH4.COM, LLC.
- Site address
- 730 RED IRON ROAD
- City
- BLACK RIVER FALLS
- State
- WI
- ZIP
- 54615
- Mailing
- 730 RED IRON ROAD, BLACK RIVER FALLS, WI 54615
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323119
- Employees
- 29
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $9282.00 · Current $6500.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Throughout the facility; Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees perform servicing tasks including, but not limited to, setup and unjamming of machines to include, but not be limited to, the Rotoflex(s), CEI(s), and the Mark Andy.
Recent events (2)
- — I (S) $6500
- — Z (S) $9282
1910.147 C07 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees as required per 29 CFR 1910.147(c)(7)(i)(A)-(C): (a) Throughout the facility; Employees were performing servicing tasks including, but not limited to, setup and unjamming of machines and were not adequately trained on safe application, usage, and deenergization of equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Production Floor; On or about August 12, 2019 energy isolating devices were not operated in such a manner as to isolate the Rotoflex die cutter from energy source(s) while an employee worked inside of the machine performing adjustments. (b) Production Floor; Energy isolating devices were not operated in such a manner as to isolate the Rotoflex, CEI, and Mark Andy die cutters from energy source(s) while employees worked inside of the machine performing adjustments.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Production Floor; On or about August 12, 2019 lockout or tagout devices were not affixed to each energy isolating device by authorized employee(s) when employee(s) were performing setup, adjustments, and/or unjamming material from the Rotoflex die cutter. (b) Production Floor; Energy isolating lockout or tagout devices were not affixed to each energy isolating device by authorized employee(s) when employee(s) were performing setup, adjustments, and/or unjamming material from the Rotoflex, CEI, and Mark Andy die cutters while employees worked inside of the machines performing adjustments.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1904.39 A02
- Issued
- Penalty
- Initial $6630.00 · Current $4640.00 Reduced
General-duty citation text
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours: (a) On or about August 12, 2019, the employer failed to report to OSHA a work-related employee amputation within twenty-four hours.
Recent events (2)
- — I (O) $4640
- — Z (O) $6630
1910.212 A02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible: (a) Production Floor; The Rotoflex (s/n 1460296) had inadequate guarding as the guards were easy to remove, and not securely affixed, exposing employees to die tooling that created nip and shear points.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at FLASH4.COM, LLC.
BLACK RIVER FALLS, WI—2026-03-03
FLASH4.COM, LLC
BLACK RIVER FALLS, WI—2023-01-31 00:00:00
FLASH4.COM, LLC
BLACK RIVER FALLS, WI—2020-03-03 00:00:00
FLASH4.COM, LLC
View FLASH4.COM, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 323119)
MINNEAPOLIS, MN—2026-01-15
110550 - EMBOSSING PLUS INC
MINNEAPOLIS, MN—2025-11-12
110251 - PRESSWRITE PRINTING INC
MINNEAPOLIS, MN—2025-10-31
110182 - THE PACKAGING LAB LLC
CENTRAL POINT, OR—2025-06-09
317740797 - STERLING BUSINESS FORMS INC
MOUNT STERLING, KY—2025-03-25
67858 - RIP TECHNOLOGIES LLC
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC
FRANKLIN, WI—2026-07-10
EDGE BROADBAND SOLUTIONS LLC
APPLETON, WI—2026-07-10
LAWRENCE UNIVERSITY OF WISCONSIN
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344244272.