Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DANVERS-T, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DANVERS-T, INC. in 99 ANDOVER STREET, DANVERS, MA 01923 (NAICS 441110). OSHA activity number 344245691.

Watch Danvers-T, INC. — free Get an email when a new federal OSHA severe-injury report for Danvers-T, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
DANVERS-T, INC.
Site address
99 ANDOVER STREET
City
DANVERS
State
MA
ZIP
01923
Mailing
99-105 ANDOVER STREET, DANVERS, MA 01923
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441110
Employees
244
Ownership type
A

6 citations on file for this inspection.

1910.107 B05 I

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $7634.00 · Current $2800.00 Reduced
29 CFR 1910.107(b)(5)(i): The average air speed over the open face of the paint spray booth was less than 100 linear feet per minute.    Collision shop floor, 99-105 Andover Street, Danvers, MA    On or about 8/20/19, booths used for the spraying of paint onto vehicles did not maintain an average air speed of 100 feet per minute.     a) The prep deck had air speeds ranging from 21 to 80 feet per minute.     b) Two bays of the spray booth had air speeds ranging from 55 to 105 feet per minute.
Recent events (3)
  • — P (S) $2800
  • — I (S) $2800
  • — Z (S) $7634

1910.134 D01 III

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $5725.00 · Current $0.00 Reduced
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:  Collision shop floor, 99-105 Andover Street, Danvers, MA  a) On or about 8/20/19, employees were not evaluated for potential exposure to chemicals that are used in the workplace, including, but not limited to n-butyl acetate, while conducting painting activities in spray booths.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5725

1910.134 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $1800.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    Collision shop floor, 99-105 Andover Street, Danvers, MA    a) On or about 8/20/19, an employee wearing a tight fitting respirator during automotive painting activities were not provided a medical evaluation to determine whether or not the employee could wear the respirator.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $0

1910.134 K

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $600.00
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary:    Collision shop floor, 99-105 Andover Street, Danvers, MA    a) On or about 8/20/19, employees were not trained on the use of tight-fitting respirators that are used while employees are performing painting tasks on cars and car parts.
Recent events (2)
  • — I (O) $600
  • — Z (S) $0

1910.242 B

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5725.00 · Current $2400.00 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    Collision shop floor, 99-105 Andover Street, Danvers, MA    a) On or about 10/3/19, employees used compressed air for cleaning that exhibited air pressure in excess of 30psi. A measurement taken demonstrated that compressed air was greater than 50psi.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $5725

1910.303 G02 I

Serious Gravity 5 1 instance 25 exposed
Issued
Abate by
Penalty
Initial $7634.00 · Current $3000.00 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    Collision shop floor, 99-105 Andover Street, Danvers, MA    a) On or about 8/20/19, employees were exposed to live electrical parts from a carbon monoxide monitoring system cabinet that had been left unlocked, and was controlled by a switch that had been wired into the system to keep the system running.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $7634

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344245691.