SUTTON, WV ·
OSHA Inspection: STRATA PRODUCTS WORLDWIDE, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of STRATA PRODUCTS WORLDWIDE, LLC in 393 EDGAR GIVEN PKWY, SUTTON, WV 26601 (NAICS 321113). OSHA activity number 344261581.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STRATA PRODUCTS WORLDWIDE, LLC
- Site address
- 393 EDGAR GIVEN PKWY
- City
- SUTTON
- State
- WV
- ZIP
- 26601
- Mailing
- 393 EDGAR GIVEN PKWY, SUTTON, WV 26601
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321113
- Employees
- 1000
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.37 A03
- Issued
- Nov 21, 2019
- Abate by
- Dec 18, 2019
- Penalty
- Initial $7,577 · Current $6,577 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: (a) Debarker - On or about 7/25/19, an emergency exit route was obstructed by vegetation, exposing employees to fire hazards.
Recent events (2)
- · I (S) $6577
- · Z (S) $7577
1910.147 A03 I
- Issued
- Nov 21, 2019
- Abate by
- Dec 18, 2019
- Penalty
- Initial $9,472 · Current $8,472 Reduced
General-duty citation text
29 CFR 1910.147(a)(3)(i): The employer did not utilize procedures for affixing appropriate lockout devices or tagout devices to energy isolating devices, and to otherwise disable machines or equipment to prevent unexpected energization, start up or release of stored energy in order to prevent injury to employees. (a) Wedge saw - On or about 7/25/19, employees did not utilize lockout and/or tagout devices during cleanup on and around the wedge saw, exposing employees to amputation hazards.
Recent events (2)
- · I (S) $8472
- · Z (S) $9472
1910.178 P01
- Issued
- Nov 21, 2019
- Abate by
- Dec 18, 2019
- Penalty
- Initial $13,260 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s) (a) Throughout the facility - On or about 7/25/19, employees were operating a Clark GCX-15E forklift with defective brakes, exposing employees to struck-by and caught-between hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $13260
1910.178 Q07
- Issued
- Nov 21, 2019
- Abate by
- Dec 18, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were being placed in services after the examination showed condition(s) adversely affecting the safety of the vehicle: (a) Throughout the facility - On or about 7/25/19, employees were operating a Clark GCX-15E forklift with defective brakes, exposing employees to struck-by and caught-between hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.212 A05
- Issued
- Nov 21, 2019
- Abate by
- Dec 18, 2019
- Penalty
- Initial $9,472 · Current $8,472 Reduced
General-duty citation text
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: (a) Link-n-logs area - On or about 7/25/19, the guard on a pedestal fan has openings greater than one half inch, exposing employees to severe injury.
Recent events (2)
- · I (S) $8472
- · Z (S) $9472
1910.305 G01 IV A
- Issued
- Nov 21, 2019
- Abate by
- Dec 18, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) Link-n-logs area - On or about 7/25/19, an extension cord was used in lieu of fixed wiring to provide power to a wall mounted fan, exposing employees to electrical hazards..
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 321113)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344261581.