OSHA Inspection: STRATA PRODUCTS WORLDWIDE, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of STRATA PRODUCTS WORLDWIDE, LLC in 393 EDGAR GIVEN PKWY, SUTTON, WV 26601 (NAICS 321113). OSHA activity number 344261581.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Strata Products Worldwide, LLC for free Get an email when a new federal OSHA severe-injury report for Strata Products Worldwide, LLC is published. One employer, no account, unsubscribe in one click.
Site address
393 EDGAR GIVEN PKWY
City
SUTTON
State
WV
ZIP
26601
Mailing
393 EDGAR GIVEN PKWY, SUTTON, WV 26601
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
1000
Ownership type
Private (A)

6 citations on file for this inspection.

1910.37 A03

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 21, 2019
Abate by
Dec 18, 2019
Penalty
Initial $7,577 · Current $6,577 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:    (a) Debarker - On or about 7/25/19, an emergency exit route was obstructed by vegetation, exposing employees to fire hazards.
Recent events (2)
  • · I (S) $6577
  • · Z (S) $7577

1910.147 A03 I

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 21, 2019
Abate by
Dec 18, 2019
Penalty
Initial $9,472 · Current $8,472 Reduced
29 CFR 1910.147(a)(3)(i): The employer did not utilize procedures for affixing appropriate lockout devices or tagout devices to energy isolating devices, and to otherwise disable machines or equipment to prevent unexpected energization, start up or release of stored energy in order to prevent injury to employees.    (a) Wedge saw - On or about 7/25/19, employees did not utilize lockout and/or tagout devices during cleanup on and around the wedge saw, exposing employees to amputation hazards.
Recent events (2)
  • · I (S) $8472
  • · Z (S) $9472

1910.178 P01

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Nov 21, 2019
Abate by
Dec 18, 2019
Penalty
Initial $13,260 · Current $0 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s)  (a) Throughout the facility - On or about 7/25/19, employees were operating a Clark GCX-15E forklift with defective brakes, exposing employees to struck-by and caught-between hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $13260

1910.178 Q07

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Nov 21, 2019
Abate by
Dec 18, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(7): Industrial trucks were being placed in services after the examination showed condition(s) adversely affecting the safety of the vehicle:  (a) Throughout the facility - On or about 7/25/19, employees were operating a Clark GCX-15E forklift with defective brakes, exposing employees to struck-by and caught-between hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.212 A05

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 21, 2019
Abate by
Dec 18, 2019
Penalty
Initial $9,472 · Current $8,472 Reduced
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch:    (a) Link-n-logs area - On or about 7/25/19, the guard on a pedestal fan has openings greater than one half inch, exposing employees to severe injury.
Recent events (2)
  • · I (S) $8472
  • · Z (S) $9472

1910.305 G01 IV A

Other-than-serious 1 instance 3 exposed
Issued
Nov 21, 2019
Abate by
Dec 18, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) Link-n-logs area - On or about 7/25/19, an extension cord was used in lieu of fixed wiring to provide power to a wall mounted fan, exposing employees to electrical hazards..
Recent events (2)
  • · I (O) $0