FORT STOCKTON, TX —
OSHA Inspection: TOTAL OILFIELD RENTAL, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TOTAL OILFIELD RENTAL, INC. in CAMERON 4-3 B #2WA AKITA RIG 523, FORT STOCKTON, TX 79735 (NAICS 213112). OSHA activity number 344265533.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TOTAL OILFIELD RENTAL, INC.
- Site address
- CAMERON 4-3 B #2WA AKITA RIG 523
- City
- FORT STOCKTON
- State
- TX
- ZIP
- 79735
- Mailing
- PO BOX 50646, CASPER, WY 82605
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 1
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.304 G05
- Issued
- Jan 21, 2020
- Penalty
- Initial $5,735 · Current $3,500 Reduced
8870
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: Shaker Area: On or about August 21, 2019 the employer did not ensure that an operational 480v V-pump was grounded when installed. Employees were exposed to burns and other hazards associated with electrical shock.
Recent events (2)
- — I (S) $3500
- — Z (S) $5735
1910.334 A02 I
- Issued
- Jan 21, 2020
- Penalty
- Initial $5,735 · Current $3,500 Reduced
8870
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): a) Shaker Area: On or about August 21, 2019 the employer did not ensure that a 480v grinder motor cable was inspected and removed when defective or damaged. This condition exposed employees to burns and other hazards associated with electrical shock. b) Shaker Area: On or about August 21, 2019 the employer did not ensure that a 480v V-Pump cable was inspected and removed when defective or damaged. This condition exposed employees to burns and other hazards associated with electrical shock.
Recent events (2)
- — I (S) $3500
- — Z (S) $5735
More inspections at Total Oilfield Rental, INC.
View Total Oilfield Rental, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 213112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344265533.