Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GKN AEROSPACE

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GKN AEROSPACE in 142 JAMES S MCDONNELL BOULEVARD, HAZELWOOD, MO 63042 (NAICS 336413). OSHA activity number 344265780.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch GKN Aerospace — free Get an email when a new federal OSHA severe-injury report for GKN Aerospace is published. One employer, no account, unsubscribe in one click.
Establishment
GKN AEROSPACE
Site address
142 JAMES S MCDONNELL BOULEVARD
City
HAZELWOOD
State
MO
ZIP
63042
Mailing
142 JAMES S MCDONNELL BOULEVARD, HAZELWOOD, MO 63042
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336413
Employees
1080
Ownership type
A

6 citations on file for this inspection.

1910.22 A02

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 17, 2019
Abate by
Nov 4, 2019
Penalty
Initial $4,831 · Current $3,382 Reduced
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained, so far as possible, in a dry condition:  Water accumulated on work area floors because of roof leaks.  At the time of the inspection, wet conditions existed and the floors had not been cleaned.  Wet floors existed at, but not limited to, posts J-5 and H-15.  Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $3381.7
  • — Z (S) $4831

1910.303 B02

Serious Gravity 1 2 instances 1 exposed
Issued
Sep 17, 2019
Abate by
Nov 4, 2019
Penalty
Initial $4,831 · Current $3,382 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a. At post H-15 a surge protector power strip, rated for home and office, was being used to power an industrial type cooling fan.  b. At post H-15, electrical power cords rated for dry conditions were run through and on a wet floor.  Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $3381.7
  • — Z (S) $4831

1910.303 G02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 17, 2019
Abate by
Nov 4, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  In the Boeing Tooling Area, a cooling fan was plugged into an extension cord with a missing equipment grounding conductor (ground pin).  Fifty-seven volts was measured on the fan metal parts.  Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 17, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  In the horizontal assembly area, a 110 V cooling fan was used with a damaged power cord.  There was no strain relief where the cord entered the fan motor cover.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 II

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 17, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service:  In the horizontal assembly area, a 110 V cooling fan was used with a damaged power cord.  There was damage to the insulation of the cord in two locations, one wrapped with electrical tape and the other with an exposed inner conductor.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A03 I

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 17, 2019
Abate by
Nov 4, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(3)(i): A flexible cord used with grounding type equipment did not contain an equipment grounding conductor:  In the Boeing Tooling Area, a cooling fan was plugged into an extension cord with a missing equipment grounding conductor (ground pin).  Fifty-seven volts was measured on the fan metal parts.  Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View GKN Aerospace's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344265780.