Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BAILY'S AUTOBODY & TOWING LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BAILY'S AUTOBODY & TOWING LLC in 16818 US 15, ALLENWOOD, PA 17810 (NAICS 811118). OSHA activity number 344268172.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Baily'S Autobody & Towing LLC — free Get an email when a new federal OSHA severe-injury report for Baily'S Autobody & Towing LLC is published. One employer, no account, unsubscribe in one click.
Site address
16818 US 15
City
ALLENWOOD
State
PA
ZIP
17810
Mailing
16818 US 15, ALLENWOOD, PA 17810
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811118
Employees
5
Ownership type
A

5 citations on file for this inspection.

1903.19 C01

Other-than-serious 3 instances 5 exposed
Issued
Jan 5, 2021
Abate by
Feb 8, 2021
Penalty
Initial $325 · Current $325
29 CFR  1903.19(c)(1):The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  Location: Facility-  On or about January 4, 2021, the employer did not certify that abatement had been completed for Citation 1 Item 1, Citation 1 Item 2b and Citation 2 Item 1.  ABATEMENT DOCUMENTATION REQUIRED FOR THIS ITEM
Recent events (1)
  • — Z (O) $325

1910.107 C06

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 30, 2019
Abate by
Feb 18, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations:  a) Paint Bay/Room: Electrical wiring and equipment including, but not limited to, electrical panel box, receptacles and lighting fixtures located within the paint bay/room were not explosion proof type approved for Class I, Group D hazardous locations, as observed on or about August 28, 2019.  Abatement Certification Required.
Recent events (1)
  • — Z (S) $0

1910.36 D02

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.36(d)(2): Exit route doors were not free of a device or alarm that could restrict emergency use of the exit route if the device or alarm fails:  a) Paint Bay/Room: The emergency exit door was secured closed using a screwdriver, as observed on or about August 28, 2019.  Abatement Observed During Inspection.
Recent events (1)
  • — Z (S) $0

1910.37 B02

Serious Gravity 1 2 instances 2 exposed
Issued
Dec 30, 2019
Abate by
Feb 18, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  a) Garage and Paint Bay: The two emergency exit doors from the garage and through the paint bay were not marked by signs reading "EXIT", as observed on or about August 28, 2019.  Abatement Certification Required.
Recent events (1)
  • — Z (S) $0

1910.253 B04 III

Other-than-serious 1 instance 2 exposed
Issued
Dec 30, 2019
Abate by
Feb 18, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour:  a) Garage: Oxygen cylinders (2) and fuel gas cylinders (acetylene-2) were in storage together and not separated by a noncombustible barrier, as observed on or about August 28, 2019.  Abatement Certification Required.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344268172.