ALLENWOOD, PA —
OSHA Inspection: BAILY'S AUTOBODY & TOWING LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BAILY'S AUTOBODY & TOWING LLC in 16818 US 15, ALLENWOOD, PA 17810 (NAICS 811118). OSHA activity number 344268172.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BAILY'S AUTOBODY & TOWING LLC
- Site address
- 16818 US 15
- City
- ALLENWOOD
- State
- PA
- ZIP
- 17810
- Mailing
- 16818 US 15, ALLENWOOD, PA 17810
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811118
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1903.19 C01
- Issued
- Jan 5, 2021
- Abate by
- Feb 8, 2021
- Penalty
- Initial $325 · Current $325
General-duty citation text
29 CFR 1903.19(c)(1):The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: Location: Facility- On or about January 4, 2021, the employer did not certify that abatement had been completed for Citation 1 Item 1, Citation 1 Item 2b and Citation 2 Item 1. ABATEMENT DOCUMENTATION REQUIRED FOR THIS ITEM
Recent events (1)
- — Z (O) $325
1910.107 C06
- Issued
- Dec 30, 2019
- Abate by
- Feb 18, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: a) Paint Bay/Room: Electrical wiring and equipment including, but not limited to, electrical panel box, receptacles and lighting fixtures located within the paint bay/room were not explosion proof type approved for Class I, Group D hazardous locations, as observed on or about August 28, 2019. Abatement Certification Required.
Recent events (1)
- — Z (S) $0
1910.36 D02
- Issued
- Dec 30, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(d)(2): Exit route doors were not free of a device or alarm that could restrict emergency use of the exit route if the device or alarm fails: a) Paint Bay/Room: The emergency exit door was secured closed using a screwdriver, as observed on or about August 28, 2019. Abatement Observed During Inspection.
Recent events (1)
- — Z (S) $0
1910.37 B02
- Issued
- Dec 30, 2019
- Abate by
- Feb 18, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a) Garage and Paint Bay: The two emergency exit doors from the garage and through the paint bay were not marked by signs reading "EXIT", as observed on or about August 28, 2019. Abatement Certification Required.
Recent events (1)
- — Z (S) $0
1910.253 B04 III
- Issued
- Dec 30, 2019
- Abate by
- Feb 18, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour: a) Garage: Oxygen cylinders (2) and fuel gas cylinders (acetylene-2) were in storage together and not separated by a noncombustible barrier, as observed on or about August 28, 2019. Abatement Certification Required.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 811118)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344268172.