On , OSHA opened a planned safety inspection of B.B.D. GROUP LLC in 4428 CHESTNUT LN NW, WASHINGTON, DC 20007 (NAICS 238130). OSHA activity number 344272901.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch B.B.D. Group LLC — free Get an email when a new federal OSHA severe-injury report for B.B.D. Group LLC is published. One employer, no account, unsubscribe in one click.
Establishment
B.B.D. GROUP LLC
Site address
4428 CHESTNUT LN NW
City
WASHINGTON
State
DC
ZIP
20007
Mailing
3705 GREENLY STREET, SILVER SPRING, MD 20906
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
8
Ownership type
A

5 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 28, 2020
Abate by
Mar 6, 2020
Penalty
Initial $2,458 · Current $2,458
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  a) On or about August 29, 2019; throughout the site; employees were not wearing eye protection while operating portable tools such as but not limited to pneumatic nail guns.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $2458

1926.501 B13

Serious Gravity 10 2 instances 4 exposed
Issued
Feb 28, 2020
Abate by
Mar 9, 2020
Penalty
Initial $4,048 · Current $4,048
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):   a) On or about August 29, 2019, roof area; employees were observed walking the top-plate and trusses while framing the new residential home without fall protection in place to protect them from falling approximately 10-feet to the wooden floor or 27-feet to ground level.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $4048

1926.1053 B01

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 28, 2020
Abate by
Mar 6, 2020
Penalty
Initial $4,048 · Current $4,048
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a) On or about August 29, 2019, second-floor area; the side rails on the 6-foot Werner step-ladder used during the framing process was 4-feet below the upper landing, exposing the employees to a fall of approximately 10-feet from the upper landing to the wooden deck.   b) On or about August 29, 2019, second-floor area; the side rails on the 8-foot Werner step-ladder used during the framing process was 2-feet below the upper landing, exposing the employees to a fall of approximately 10-feet from the upper landing to the wooden deck.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records
Recent events (1)
  • — Z (S) $4048

1926.1053 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 28, 2020
Abate by
Mar 6, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:  a) On or about August 29, 2019; second floor; employees used the top step of step-ladders that were too short for the application to access the the top-plate area exposing them to an estimated fall of 10-feet to the wooden deck.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records
Recent events (1)
  • — Z (S) $0

1926.503 B01

Other-than-serious 1 instance 4 exposed
Issued
Feb 28, 2020
Abate by
Mar 5, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer.  a) On or about August 29, 2019; throughout the site; the employer had not certified the fall protection training for employees who were exposed to falls up to approximately 27 feet while completing framing work.     In accordance with 29 CFR 1903.19(d), abatement ce1tification is required for this violation (using the Certification of Corrective Action Worksheet