HARRISVILLE, RI —
OSHA Inspection: DAVID SHAYER ROOFING
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DAVID SHAYER ROOFING in 21 EAST AVE., HARRISVILLE, RI 02830 (NAICS 238160). OSHA activity number 344274113.
Where did this inspection happen?
- Establishment
- DAVID SHAYER ROOFING
- Site address
- 21 EAST AVE.
- City
- HARRISVILLE
- State
- RI
- ZIP
- 02830
- Mailing
- 32B ZENNON ST., MAPLEVILLE, RI 02839
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.100 A
- Issued
- Abate by
- Penalty
- Initial $2842.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: (a) Three-story existing residential structure: An employee was exposed to struck-by overhead hazards from construction materials while conducting housekeeping construction work, and was not protected by a protective helmet.
Recent events (2)
- — I (S) $1500
- — Z (S) $2842
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $3978.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): (a) Three-story existing residential structure: Two (2) employees were exposed to an approximately 20-foot fall hazard while working on a roof, where fall protection had not been used or provided.
Recent events (2)
- — I (S) $2000
- — Z (S) $3978
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $2842.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) Three-story existing residential structure: Two employees were exposed to a fall hazard while using an aluminum portable ladder that was not properly extended to access an upper landing surface.
Recent events (2)
- — I (O) $0
- — Z (S) $2842
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in RI
PAWTUCKET, RI—2026-07-16
INTERNATIONAL PACKAGING CORPORATION
WARWICK, RI—2026-07-16
LYON PROPERTY MANAGEMENT, LLC
LINCOLN, RI—2026-07-14
TFORCE FREIGHT
JOHNSTON, RI—2026-07-14
WEST BAY RESIDENTIAL SERVICES INC.
NEWPORT, RI—2026-07-10
STEVEN POSTHUMA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344274113.