Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALLIED STONE INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of ALLIED STONE INC. in 2315 CROWN RD., DALLAS, TX 75229 (NAICS 327991). OSHA activity number 344276969.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Allied Stone INC. — free Get an email when a new federal OSHA severe-injury report for Allied Stone INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ALLIED STONE INC.
Site address
2315 CROWN RD.
City
DALLAS
State
TX
ZIP
75229
Mailing
2405 CROWN RD., DALLAS, TX 75229
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327991
Employees
110
Ownership type
A

7 citations on file for this inspection.

1910.1053 C

Other-than-serious Gravity 10 1 instance 3 exposed
Issued
Nov 13, 2019
Abate by
Mar 30, 2020
Penalty
Initial $13,260 · Current $6,600 Reduced
29 CFR 1910.1053(c): The employer did not ensure that no employee was exposed to an airborne concentration of respirable crystalline silica in excess of 50 ug/m3, calculated as an 8-hour TWA:   (a) A grinder employee was performing hand grinding operations and was exposed to respirable crystalline silica at an eight-hour time-weighted average of 57.9 micrograms per cubic meter of air, approximately 1.15 times 50 micrograms per cubic meter of air. This limit is established to prevent silicosis and lung cancer. Sampling was performed for 456 minutes. Zero exposure was assumed for the unsampled time of 24 minutes.
Recent events (3)
  • — F (O) $6600
  • — C (S) $13260
  • — Z (S) $13260

1910.1053 F01

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Nov 13, 2019
Abate by
Mar 30, 2020
Penalty
Initial $0 · Current $0

Hazardous substances 9000

29 CFR 1910.1053(f)(1): The employer did not use engineering and work practice controls to reduce and maintain employee exposure to respirable crystalline silica to or below the PEL, unless the employer can demonstrate that such controls are not feasible:  (a) A grinder employee was performing hand grinding operations and was exposed to respirable crystalline silica at an eight-hour time-weighted average of 57.9 micrograms per cubic meter of air, approximately 1.15 times 50 micrograms per cubic meter of air. This limit is established to prevent silicosis and lung cancer. Sampling was performed for 456 minutes. Zero exposure was assumed for the unsampled time of 24 minutes.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.1053 E01

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Nov 13, 2019
Abate by
Dec 10, 2019
Penalty
Initial $13,260 · Current $0 Reduced

Hazardous substances 9000

29 CFR 1910.1053(e)(1): The employer did not establish a regulated area wherever an employee's exposure to airborne concentrations of respirable crystalline silica was, or could have been reasonably expected to be, in excess of the PEL:   (a) The employer did not establish a regulated area for employee(s) exposed to airborne concentrations of respirable crystalline silica above the Permissible Exposure Limit (PEL). Personal air monitoring conducted at the workplace showed that an employee was exposed to airborne concentrations of  57.9 micrograms per cubic meter of air which exceeded the PEL of 50 micrograms per cubic meter of air by 1.15 times respectively. This limit is established to prevent silicosis and lung cancer. Employee(s) were assigned duties such as but not limited to grinding granite countertops.
Recent events (3)
  • — F (S) $0
  • — C (S) $13260
  • — Z (S) $13260

1910.1053 J02

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Nov 13, 2019
Abate by
Dec 10, 2019
Penalty
Initial $0 · Current $0

Hazardous substances 9000

29 CFR 1910.1053(j)(2): The employer did not post signs at all entrances to regulated areas that bear the following legend: DANGER, RESPIRABLE CRYSTALLINE SILICA, MAY CAUSE CANCER, CAUSES DAMAGE TO LUNGS, WEAR RESPIRATORY PROTECTION IN THIS AREA, AUTHORIZED PERSONNEL ONLY:   (a) The employer not post the following warning signs DANGER- RESPIRABLE CRYSTALLINE SILICA-MAY CAUSE CANCER-CAUSES DAMAGE TO LUNGS- WEAR RESPIRATORY PROTECTION IN THIS AREA- AUTHORIZED PERSONNEL ONLY, at the entrance of the Grinding and Polishing Area where the Permissible Exposure Limit (PEL) were exceeded. Personal air monitoring conducted at the workplace showed that employee(s) were exposed to airborne concentrations of 57.9 micrograms per cubic meter of air which exceeded the PEL of 50 micrograms per cubic meter of air by 1.15 times respectively. This limit is established to prevent silicosis and lung cancer.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.1053 G01

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Nov 13, 2019
Abate by
Dec 10, 2019
Penalty
Initial $13,260 · Current $0 Reduced

Hazardous substances 9000

29 CFR 1910.1053(g)(1): Where respiratory protection was required by this section, the employer did not provide each employee an appropriate respirator that complied with the requirements of this paragraph and 29 CFR 1910.134:  (a) The employer did not provide and require usage of an appropriate respirator for an employee exposed to airborne concentrations of respirable crystalline silica above the Permissible Exposure Limit (PEL). Personal air monitoring conducted at the workplace showed that employee(s) were exposed to airborne concentrations of 57.9 micrograms per cubic meter of air which exceeded the PEL of 50 micrograms per cubic meter of by 1.15 times respectively. This limit is established to prevent silicosis and lung cancer. An employee was assigned duties such as but not limited to grinding and polishing granite countertops.
Recent events (3)
  • — F (S) $0
  • — C (S) $13260
  • — Z (S) $13260

1910.134 A02

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Nov 13, 2019
Abate by
Dec 10, 2019
Penalty
Initial $0 · Current $0

Hazardous substances 9000

29 CFR 1910.134(a)(2): A respirator was not provided by the employer to each employee when such equipment was necessary to protect the health of the employee:   (a) The employer did not provide and require usage of an appropriate respirator when such equipment was necessary to protect the health of an employee. An employee was exposed to airborne concentrations of respirable crystalline silica above the Permissible Exposure Limit (PEL).  Personal air monitoring conducted at the workplace showed that employee(s) were exposed to airborne concentrations of 57.9 micrograms per cubic meter of air which exceeded the PEL of 50 micrograms per cubic meter of by 1.15 times respectively. This limit is established to prevent silicosis and lung cancer. An employee was assigned duties such as but not limited to grinding and polishing granite countertops.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.1053 I01 I

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Nov 13, 2019
Abate by
Dec 10, 2019
Penalty
Initial $13,260 · Current $0 Reduced
29 CFR 1910.1053(i)(1)(i): The employer did not make medical surveillance available at no cost to each employee, and at a reasonable time and place, for each employee who has been occupationally exposed to respirable crystalline silica at or above the action level for 30 or more days per year:   (a) The employer did not institute a medical surveillance program for all employee(s) who were exposed respirable crystalline silica at or above the action level for 30 days per year. Personal air monitoring indicated that one employee was exposed to airborne respirable crystalline silica concentrations which exceeded the Permissible Exposure Limit (PEL).This limit is established to prevent silicosis and lung cancer. Employees were assigned duties such as but not limited to operating and grinding with portable hand grinders on granite countertops.
Recent events (3)
  • — F (S) $0
  • — C (S) $13260
  • — Z (S) $13260

View Allied Stone INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344276969.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.