AUSTIN, TX —
OSHA Inspection: GABRIEL SILVA HERNANDEZ
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of GABRIEL SILVA HERNANDEZ in 3220 DUVAL RD., AUSTIN, TX 78759 (NAICS 238130). OSHA activity number 344279583.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GABRIEL SILVA HERNANDEZ
- Site address
- 3220 DUVAL RD.
- City
- AUSTIN
- State
- TX
- ZIP
- 78759
- Mailing
- 104 SUNNYVALE, GEORGETOWN, TX 78626
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.403 B02
- Issued
- Dec 4, 2019
- Abate by
- Dec 10, 2019
- Penalty
- Initial $3,978 · Current $3,978
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: On or about August 28, 2019, and at times prior thereto, the employer installed a makeshift power connection by splicing together vehicle jumper cables and a flexible cord and attaching to the outdoor air conditioning unit electrical bus bar. The assembly was used to power portable hand tools, exposing employees to an electrical shock hazard.
Recent events (1)
- — Z (S) $3978
1926.405 G02 III
- Issued
- Dec 4, 2019
- Abate by
- Dec 10, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap: a) On or about August 28, 2019, and at times prior thereto, the employer installed a makeshift power connection by splicing together vehicle jumper cables and a flexible cord and attaching to the outdoor air conditioning unit electrical bus bar. The assembly was used to power portable hand tools, exposing employees to an electrical shock hazard. b) On or about August 28, 2019, and in times prior thereto, on the roof, excessively worn cables and cords were spliced with wire nuts, without insulating materials equivalent to the original cords.
Recent events (1)
- — Z (S) $0
1926.503 A01
- Issued
- Dec 4, 2019
- Abate by
- Dec 10, 2019
- Penalty
- Initial $3,978 · Current $3,978
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: The employer did not provide a training program for all employees exposed to fall hazards. The program shall include training and instruction in the following areas: a) The recognition and identification of fall hazards in the work area; b) The use and operation of guardrail systems (including perimeter safety cable systems), personal fall arrest systems, positioning device systems, fall restraint systems, safety net systems, and other protection to be used; c) The correct procedures for erecting, maintaining, disassembling, and inspecting the fall protection systems to be used; d) The procedures to be followed to prevent falls to lower levels and through or into holes and openings in walking/working surfaces and walls; and e) The fall protection requirements of this subpart.
Recent events (1)
- — Z (S) $3978
1926.602 C01 II
- Issued
- Dec 4, 2019
- Abate by
- Dec 10, 2019
- Penalty
- Initial $2,842 · Current $2,842
General-duty citation text
29 CFR 1926.602(c)(1)(ii): Modifications or additions affecting the safe operation of the equipment were made without the manufacturer's written approval: Note: If such modifications or changes are made, the capacity, operation, and maintenance instruction plates, tags, or decals shall be changed accordingly: On or about August 28, 2019, and at times prior thereto, the employer built and attached a wooden box to the forklift for loading tools and materials to the roof without the manufacturer's written approval, exposing employees to being struck by the box.
Recent events (1)
- — Z (S) $2842
1926.1053 B01
- Issued
- Dec 4, 2019
- Abate by
- Dec 10, 2019
- Penalty
- Initial $3,978 · Current $3,978
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9m) above the upper landing surface to which the ladder was used to gain access: On or about August 28, 2019, and at times prior thereto, employees were accessing the roof of the three story apartment building up to approximately 30 feet high to replace the siding on the chimney without the ladder side rails extending at least 3 feet above the upper landing, exposing employees to a fall hazard.
Recent events (1)
- — Z (S) $3978
1926.1053 B04
- Issued
- Dec 4, 2019
- Abate by
- Dec 10, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: On or about August 28, 2019, and at times prior thereto, employees were accessing the roof of the three story apartment building to replace the siding on the chimney using "A" frame step ladders as non-self supporting ladders, exposing employees to a fall hazard.
Recent events (1)
- — Z (S) $0
1926.1053 B05 I
- Issued
- Dec 4, 2019
- Abate by
- Dec 10, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support): On or about August 28, 2019, and at times prior thereto, employees were accessing the roof of the three story apartment building up to approximately 30 feet high to replace the siding on the chimney without the ladder used at one-quarter of the working length of the ladder, exposing employees to a fall hazard.
Recent events (1)
- — Z (S) $0
1926.501 B13
- Issued
- Dec 4, 2019
- Abate by
- Dec 10, 2019
- Penalty
- Initial $26,520 · Current $26,520
General-duty citation text
29 CFR 1926.501(b)(13): Employee(s) engaged in residential construction 6 feet (1.8 m) or more above lower levels were not protected from falling by the use of guardrail systems, safety net systems or personal fall arrest systems nor was an alternative fall protection plan which meets the requirements of 1926.502(k) developed and implemented: On or about August 28, 2019, and at times prior thereto, employees were replacing the siding on the chimneys of the apartment complex up to approximately 30 feet high without fall protection, exposing employees to a fall hazard.
Recent events (1)
- — Z (W) $26520
More inspections in this industry (NAICS 238130)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344279583.