Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PICO INDUSTRIES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PICO INDUSTRIES, INC. in 1822 WILBERGER ST. NW, WASHINGTON, DC 20005 (NAICS 238120). OSHA activity number 344279898.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pico Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Pico Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1822 WILBERGER ST. NW
City
WASHINGTON
State
DC
ZIP
20005
Mailing
1922 BENHILL AVE., BALTIMORE, MD 21226
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238120
Employees
3
Ownership type
A

5 citations on file for this inspection.

1926.760 A01

Serious Gravity 10 2 instances 3 exposed
Issued
Feb 28, 2020
Abate by
Mar 11, 2020
Penalty
Initial $9,446 · Current $9,446
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems:   (a)    Fourth Floor Framing - On or about August 28, 2019, structural steel workers, who were exposed to a 20 foot fall, were observed landing loads of steel decking and web joists lowered to them from a truck crane and were not using personal fall protection during that process.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $9446

1926.760 A02

Serious Gravity 5 2 instances 3 exposed
Issued
Feb 28, 2020
Abate by
Mar 18, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.760(a)(2): Perimeter safety cables were not installed on final interior and exterior perimeters on the floors as soon as the metal decking was installed:   (a)    Second Floor Framing, South Side  On or about August 28, 2019, workers were exposed to a 10 foot fall for safety cables were not installed on the open side of a steel framed multi-story building where this contractor had completed decking the floor.   (b)   Second Floor Framing, West Side - On or about August 28, 2019, workers were exposed to a 10 foot fall for safety cables were not installed on the open side of a steel framed multi-story building where this contractor had completed decking the floor.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 28, 2020
Penalty
Initial $6,882 · Current $6,882
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  (a)  Second Floor, Existing Building - On or about August 28, 2019, workers were exposed to a 10 foot fall from an eight foot long portable step ladder that did not extend above the steel decking and which was used to access their work area.   No abatement certification or documentation required for this item.
Recent events (1)
  • — Z (S) $6882

1926.1053 B04

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 28, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:   a)  Second Floor, Existing Building  On or about August 28, 2019, workers were exposed to a 10 foot fall when an 8 foot long portable step ladder was not used for the purpose it was intended, in that, the ladder sections were folded together and leaned up against a brick wall while it was used by workers to access their work area.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).   No abatement certification or documentation required for this item.
Recent events (1)
  • — Z (S) $0

1926.1053 B13

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 28, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:     (a)  Second Floor, Existing Building  On or about August 28, 2019, workers were exposed to a 10 foot fall while using the top of an eight foot long portable step ladder as a step as they used the ladder to access their work area.    No abatement certification or documentation required for this item.
Recent events (1)
  • — Z (S) $0

View Pico Industries, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344279898.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.