Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: M-FAB LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of M-FAB LLC in 52 NORWOOD STREET, TORRINGTON, CT 06790 (NAICS 332611). OSHA activity number 344280037.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M-Fab LLC — free Get an email when a new federal OSHA severe-injury report for M-Fab LLC is published. One employer, no account, unsubscribe in one click.
Establishment
M-FAB LLC
Site address
52 NORWOOD STREET
City
TORRINGTON
State
CT
ZIP
06790
Mailing
52 NORWOOD STREET, TORRINGTON, CT 06790
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332611
Employees
3
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 2 instances 1 exposed
Issued
Oct 8, 2019
Abate by
Nov 26, 2019
Penalty
Initial $2,842 · Current $2,842
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating and reciprocating parts:   Production Area:  On, or about, September 30, 2019, employees exposure to rotating and reciprocating parts was not minimized by an enclosure guard or other equally effective means in that the following Nilson fourslide machines were not provided with a two hand jog control for set-up:  A.  Green Four Slide, Model S-432. B.  Grey Four Slide, Model S-432.
Recent events (3)
  • — F (S) $2842
  • — C (S) $2842
  • — Z (S) $2842

1910.303 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 8, 2019
Abate by
Nov 26, 2019
Penalty
Initial $1,705 · Current $1,705
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    Production Area, Gray Nilson Fourslide Machine:  On, or about, September 30, 2019, a relocatable power tap was energized through a green extension cord for the handle dispenser.  The use of an extension cord to energize a relocatable power tap is not an acceptable use under the UL White Book which contains instructions for use of relocatable power taps.
Recent events (3)
  • — F (S) $1705
  • — C (S) $1705
  • — Z (S) $1705

1910.305 G01 IV D

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 8, 2019
Abate by
Nov 26, 2019
Penalty
Initial $3,410 · Current $0 Reduced
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were used where attached to building surfaces:    Production Area, Gray Nilson Fourslide Machine:  On, or about, September 30, 2019, the handle dispenser was energized through a series of two extension cords and a relocatable power tap.      The (employer name) was previously cited for a violation of an equivalent standard [29 CFR 1910.305(g)(1)(I)(A)], which was contained in OSHA Inspection Number 1007450, Citation Number 1, Item Number 5b and was affirmed as a Final Order on January 16, 2015, with respect to a workplace located at Torrington, Connecticut.
Recent events (3)
  • — F (S) $0
  • — C (R) $3410
  • — Z (R) $3410

1910.217 E01 I C

Other-than-serious 1 instance 1 exposed
Issued
Oct 8, 2019
Abate by
Nov 26, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.217(e)(1)(i)(C):  The employer shall maintain a certification record of each inspection, and each maintenance and repair task performed, under the general component of the inspection program that includes the date of the inspection, maintenance, or repair work, the signature of the person who performed the inspection, maintenance, or repair work, and the serial number, or other identifier, of the power press inspected, maintained, and repaired:  Production Area:  On, or about, September 30, 2019, the employer had not maintained inspection records for the Precision Welder and Flexipress Corp. straight-sided partial revolution  mechanical power press.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View M-Fab LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344280037.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.