Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ATLANTA STRUCTURAL CONCRETE COMPANY

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ATLANTA STRUCTURAL CONCRETE COMPANY in 80 DEHUNT DRIVE, BUCHANAN, GA 30113 (NAICS 327390). OSHA activity number 344280557.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Atlanta Structural Concrete Company — free Get an email when a new federal OSHA severe-injury report for Atlanta Structural Concrete Company is published. One employer, no account, unsubscribe in one click.
Site address
80 DEHUNT DRIVE
City
BUCHANAN
State
GA
ZIP
30113
Mailing
P.O. BOX 1009, BUCHANAN, GA 30113
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
120
Ownership type
A

4 citations on file for this inspection.

1910.134 C01

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Feb 25, 2020
Abate by
Mar 13, 2020
Penalty
Initial $3,982 · Current $0 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  Yard Area, Sandblasting Area:  On or about August 29, 2019, and at times prior, the employer exposed employees to respiratory hazards in that the employer provided supplied air hoods for use by employees during abrasive blasting and mandatory use filtering facepieces for use by employees while cutting and grinding but did not develop and implement a written respiratory protection program.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3982

1910.134 E01

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Feb 25, 2020
Abate by
Mar 13, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  Yard Area, Sandblasting Area:  On or about August 29, 2019, and at times prior, the employer exposed employees to respiratory hazards in that the employer provided Mercer, D10008N filtering facepieces for mandatory use by employees while cutting and grinding but did ensure that affected employee medical evaluations addressed tight-fitting, filtering facepiece use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F02

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Feb 25, 2020
Abate by
Mar 13, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:  Yard Area, Sandblasting Area:  On or about August 29, 2019, and at times prior, the employer exposed employees to respiratory hazards in that the employer provided Mercer, D10008N filtering facepieces for mandatory use by employees while cutting and grinding but did provide fit testing before the employees were required to use the respirator.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 I01 II

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 25, 2020
Abate by
Mar 13, 2020
Penalty
Initial $0 · Current $3,982
29 CFR 1910.134(i)(1)(ii): The employer did not ensure that compressed air met the requirements for Grade D breathing air as described in the ANSI/Compressed Gas Association Commodity Specification G-7.1-1989:    Yard Area, Abrasive Blasting Area:  On or about August 27, 2019, and at times prior, the employer exposed employees to hazards associated with carbon monoxide, oxides of nitrogen and other air quality hazards where the employer did not ensure that the breathing air provided by an Atlas Copco XAS JD6 compressor met the minimum criteria for Grade D air.
Recent events (2)
  • — I (S) $3982
  • — Z (S) $0

View Atlanta Structural Concrete Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344280557.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.